Pulsed-Field-Gradient Measurements of Time-Dependent Gas Diffusion
✍ Scribed by Ross W. Mair; David G. Cory; Sharon Peled; Ching-Hua Tseng; Samuel Patz; Ronald L. Walsworth
- Publisher
- Elsevier Science
- Year
- 1998
- Tongue
- English
- Weight
- 155 KB
- Volume
- 135
- Category
- Article
- ISSN
- 1090-7807
No coin nor oath required. For personal study only.
✦ Synopsis
Pulsed-field-gradient NMR techniques are demonstrated for measurements of time-dependent gas diffusion. The standard PGSE technique and variants, applied to a free gas mixture of thermally polarized xenon and O2, are found to provide a reproducible measure of the xenon diffusion coefficient (5.71 x 10(-6) m2 s-1 for 1 atm of pure xenon), in excellent agreement with previous, non-NMR measurements. The utility of pulsed-field-gradient NMR techniques is demonstrated by the first measurement of time-dependent (i.e., restricted) gas diffusion inside a porous medium (a random pack of glass beads), with results that agree well with theory. Two modified NMR pulse sequences derived from the PGSE technique (named the Pulsed Gradient Echo, or PGE, and the Pulsed Gradient Multiple Spin Echo, or PGMSE) are also applied to measurements of time dependent diffusion of laser polarized xenon gas, with results in good agreement with previous measurements on thermally polarized gas. The PGMSE technique is found to be superior to the PGE method, and to standard PGSE techniques and variants, for efficiently measuring laser polarized noble gas diffusion over a wide range of diffusion times.
📜 SIMILAR VOLUMES
Over the past decade several pulsed field gradient stimulated-echo methods have been presented for diffusion measurements in heterogeneous media. These methods have reduced or eliminated the coupling between the applied magnetic field gradient and a constant internal magnetic field gradient caused b
## Abstract We have studied the temperature dependence of the tracer diffusion coefficient of carbonmonoxy hemoglobin A (HbA‐CO) by means of pulsed‐field gradient nmr (PFG‐nmr). Measurements were made over the temperature range from 15 to 35°C for samples having concentrations 7.4 and 16.7 g/dL. No
## Abstract The self‐association of aqueous catechin as a function of concentration was monitored through variations in ^1^H chemical shifts, proton __T__~1~ and __T__~2~ data and translational diffusion coefficients obtained with the pulsed‐field gradient spin‐echo method. The latter approach is v