## High-performance capillary electrophoretic separation of proteins and peptides using a bonded hydrophilic phase capillary High performance capillary electrophoresis (HPCE) was applied to the separation of protein and peptide mixtures with molecular masses ranging from 1300 to 96000 Da using a n
Protein and peptide separations on high surface area capillaries
β Scribed by Joseph J. Pesek; Maria T. Matyska; Sally Swedberg; Sharmila Udivar
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 98 KB
- Volume
- 20
- Category
- Article
- ISSN
- 0173-0835
No coin nor oath required. For personal study only.
β¦ Synopsis
Protein and peptide separations on high surface area capillaries
A 50 mm capillary that has been etched with ammonium hydrogen difluoride is evaluated as a separation medium for capillary electrochromatography. For a tryptic digest of transferrin, the etched capillary gave better resolution (more peaks in the overall peptide map) and longer retention than separations done under identical experimental conditions on an unetched fused-silica capillary. Resolution on the etched capillary was improved by lowering the voltage from 300 to 267 V/cm. A four-component protein sample also resulted in longer retention on an echted capillary than on an unetched fused-silica capillary that were both coated with Polybrene. After correction for differences in electroosmotic flow between the two capillaries, the calculated electrophoretic mobilities for all four proteins were lower on the etched capillary than on the unetched fused-silica capillary. The results of both the tryptic digest and protein experiments strongly indicate the presence of chromatographic effects on the etched capillary that contribute to the increased retention and improved resolution with respect to the unetched fused-silica capillary.
π SIMILAR VOLUMES
A range of high-performance liquid chromatography (HPLC) columns with internal diameters of 0.25 to 1.8 mm have been constructed by securing glass or plastic tubing into standard HPLC fittings. These were packed with chromatographic materials chosen for operation at moderate pressures with high flow
## Abstract The effects of the sample matrix on the separation of peptides by HPCE has been investigated. Under both acidic and alkaline conditions, use of 25β30 mM salts in the sample zone resulted in much better resolution than did 100 mM salts. Prefocusing effects and acceleration of elution wer
A novel on-line 2-D system was developed for peptide and protein mapping. The system combines capillary IEF (cIEF) with pressurized CEC (pCEC) using a micro-injection valve as the interface. Sample fractions, which were focused and separated in the firstdimension cIEF based on their differences in p