Post-processing correction of the endorectal coil reception effects in MR spectroscopic imaging of the prostate
✍ Scribed by Susan M. Noworolski; Galen D. Reed; John Kurhanewicz; Daniel B. Vigneron
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 684 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose:
To develop and validate a post‐processing correction algorithm to remove the effect of the inhomogeneous reception profile of the endorectal coil on MR spectroscopic imaging (MRSI) data.
Materials and Methods:
A post‐processing algorithm to correct for the endorectal coil reception effects on MRSI data was developed based upon theoretical modeling of the endorectal coil reception profile and of the spatial saturation pulse profiles. This algorithm was evaluated on three‐dimensional (3D) MRSI data acquired at 3T from a uniform phantom and from 18 patients with known or suspected prostate cancer.
Results:
For the phantom data, the coefficient of variation of metabolite peak areas decreased 16% to 46% and the peak area distributions became more Gaussian with correction, as demonstrated by higher Q‐Q plot linear correlations (R^2^ = 0.98 ± 0.007 vs. R^2^ = 0.89 ± 0.066). Across the 18 patients, the mean coefficient of variation for suppressed water decreased significantly, from 0.95 ± 0.18, to 0.66 ± 0.11, (P < 10^−6^, paired t‐test) and the linear correlations of the Q‐Q plots for the suppressed water increased from R^2^ = 0.91 to R^2^ = 0.95 (P = 0.0083, paired t‐test) with correction.
Conclusion:
An algorithm for reducing the effect of the inhomogeneous reception profile in endorectal coil acquired 3D MRSI prostate data was demonstrated, illustrating increased homogeneity and more Gaussian peak area distributions. J. Magn. Reson. Imaging 2010;32:654–662. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract The value of inversion‐recovery (IR) sequences in the diagnosis and staging of prostatic carcinoma with magnetic resonance (MR) imaging was studied. Twenty‐six patients with carcinoma of the prostate were imaged at 1.5 T with an endorectal surface coil and with a variety of IR sequences
## Abstract An analytic correction method was developed and applied to correct the signal intensity nonuniformity caused by the inhomogeneous reception profile of surface coils used—because of their higher sensitivity—for magnetic resonance imaging of the brain at 1.5 T. The reception profile was a
## Abstract ## Purpose To compare the data quality and ease of use of four endorectal‐coil probe setups for prostate MRI. ## Materials and Methods Four endorectal‐coil probe setups were compared: 1) air‐inflated probe; 2) perfluorocarbon (PFC)‐inflated probe; 3) rigid, smaller prototype coil; an
## Abstract Proton MR spectroscopic imaging (^1^H‐MRSI) of the human prostate, which has an interesting clinical potential, may be improved by increasing the magnetic field strength from 1.5T to 3T. Both theoretical and practical considerations are necessary to optimize the pulse timing for spectro
## Background: Little effort has been made at the quantitative and qualitative evaluation of patients with prostate carcinoma, including downsizing and downstaging of the primary lesion, after conservative therapy. the current study was undertaken to investigate the qualitative and quantitative eff