## Abstract ## Purpose: To develop and validate a post‐processing correction algorithm to remove the effect of the inhomogeneous reception profile of the endorectal coil on MR spectroscopic imaging (MRSI) data. ## Materials and Methods: A post‐processing algorithm to correct for the endorectal c
A simple method for the correction of endorectal surface coil inhomogeneity in prostate imaging
✍ Scribed by Gary P. Liney; Lindsay W. Turnbull; Adrian J. Knowles
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 573 KB
- Volume
- 8
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A simple method is described that corrects for the intensity inhomogeneity experienced when using endorectal surface coils in prostate imaging. The method uses a series of proton‐density‐weighted images, which are acquired to demonstrate the sensitivity profile of the coil and used to correct T2‐weighted images acquired in the same plane. The results demonstrate improved image uniformity and visualization of prostatic anatomy.
📜 SIMILAR VOLUMES
## Abstract We have designed a solid endorectal receiver coil for MRI of the prostate. The coil provided an improved signal‐to‐noise ratio up to 5 cm from its surface when compared with a standard pelvic phased array. This preliminary report describes 16 patients who were imaged using this coil, se
## Abstract We evaluate a wavelet‐based algorithm to estimate the coil sensitivity modulation from surface coils. This information is used to improve the image homogeneity of magnetic resonance imaging when a surface coil is used for reception, and to increase image encoding speed by reconstructing
## Abstract ## Purpose To compare the data quality and ease of use of four endorectal‐coil probe setups for prostate MRI. ## Materials and Methods Four endorectal‐coil probe setups were compared: 1) air‐inflated probe; 2) perfluorocarbon (PFC)‐inflated probe; 3) rigid, smaller prototype coil; an
## Abstract A study was performed to determine whether an implanted, inductively coupled nuclear magnetic resonance (NMR) imaging spine coil could provide a significant gain in signal‐to‐noise ratio (SNR) on images of the spinal cord relative to the SNR of optimized surface coils. Implanted coils w
Radioactive cesium ions have been used as indicators for the unequal distribution of electrolytes in two-compartment systems which contain nondiffusible macroions in one of the compartments. This method allows the precise determination of the Donnan ratio under conditions in which binding studies of