## Abstract ## Purpose: To determine the reproducibility of 3D proton magnetic resonance spectroscopic imaging (^1^H‐MRSI) of the human prostate in a multicenter setting at 1.5T. ## Materials and Methods: Fourteen subjects were measured twice with 3D point‐resolved spectroscopy (PRESS) ^1^H‐MRSI
Optimal timing for in vivo 1H-MR spectroscopic imaging of the human prostate at 3T
✍ Scribed by Tom W.J. Scheenen; Giulio Gambarota; Elisabeth Weiland; Dennis W.J. Klomp; Jurgen J. Fütterer; Jelle O. Barentsz; Arend Heerschap
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 706 KB
- Volume
- 53
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Proton MR spectroscopic imaging (^1^H‐MRSI) of the human prostate, which has an interesting clinical potential, may be improved by increasing the magnetic field strength from 1.5T to 3T. Both theoretical and practical considerations are necessary to optimize the pulse timing for spectroscopic imaging of the human prostate at 3T. For in vivo detection of the strongly coupled spin system of citrate, not only should the spectral shape of the signal be easy to identify, but the timing used should produce MR signals at reasonably short echo times (TEs). In this study the spectral shape of the methylene protons of citrate was simulated with density matrix calculations and checked with phantom measurements. Different calculated optimal spectral shapes were measured in patients with prostate cancer with a 2D spectroscopic imaging sequence. T~1~ and T~2~ relaxation times were calculated for citrate and choline, the two major metabolites of interest in the prostate. We conclude that the optimum timing for in vivo point‐resolved spectroscopy (PRESS) imaging at 3T is an interpulse timing sequence of 90° ‐ 25 ms ‐ 180° ‐ 37.5 ms ‐ 180° ‐ 12.5 ms ‐ echo. A short repetition time (TR) of 750 ms partially saturates choline signals, but increases the SNR per unit time for citrate, and accommodates a maximum number of weighted averages of an elliptically sampled k‐space for accurate localization and minimal contamination of the individual spectra. This is illustrated by means of a 3D spectroscopic imaging experiment in a complete prostate in vivo. Magn Reson Med 53:1268–1274, 2005. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To compare the spectral quality of short echo time (TE) MR spectroscopic imaging (MRSI, TE = 30 msec) with long‐TE MRSI (TE = 144 msec) at 3 Tesla in normal brain and tumor tissue. ## Materials and Methods Spectroscopic imaging (chemical‐shift imaging (CSI)) data of 32 pat
## Abstract Citrate is a secretory product of the normal prostate, a lack of citrate in prostate tissue is expected to be pathognomonic for adenocarcinoma. In the present study proton AB‐signal characteristics of citrate at low field strength of 1.5 T were investigated by __volume selective spectro
## Abstract A new ^1^H‐MRS filtering strategy for selective measurement of glycine (Gly) in human brain in vivo at 3.0T is proposed. Investigation of multiple refocusing following a 90° excitation pulse indicated that triple refocusing is most effective for suppression of the strongly coupled reson
In previous in situ point-resolved spectroscopy (PRESS) three-dimensional (3D) 1H magnetic resonance (MR) spectroscopic imaging studies, it has been demonstrated that the ratio of prostatic metabolites can noninvasively discriminate prostate cancer from surrounding normal tissue. However, in these s