𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Photodissociation of alkane ions in the source of a mass spectrometer: A potential analytical technique

✍ Scribed by M. S. Kim; T. G. Morgan; E. E. Kingston; F. M. Harris


Publisher
John Wiley and Sons
Year
1983
Tongue
English
Weight
487 KB
Volume
18
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Metal-metal chelate exchange reactions i
✍ J. K. Terlouw; J. J. De Ridder πŸ“‚ Article πŸ“… 1971 πŸ› John Wiley and Sons 🌐 English βš– 226 KB

In the mass spectra of several transition metal chelates with diethyldithiocarbamate as a ligand, intense peaks are present which could be assigned to extraneous metal (particularly nickel) containing ions. Using an Au-Rh coated ion source, evidence was obtained for the occurrence of exchange reacti

Variation of relative ion abundances wit
✍ Ian Howe; Dudley H. Williams πŸ“‚ Article πŸ“… 1969 πŸ› John Wiley and Sons 🌐 English βš– 255 KB

Calculations have been carried out, using the Quasi-Equilibrium Theory of Mass Spectra to show that a decrease in penetration of the accelerating field into the ion source of a mass spectrometer may significantly increase the number of primary daughter ions [A]+ produced from a molecular ion [MI+ in

Non-thermal internal energy distribution
✍ David Rondeau; Nicolas Galland; Emilie-Laure Zins; Claude Pepe; LΓ‘szlΓ³ Drahos; K πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 358 KB

## Abstract The internal energy distribution __P__(__E__~int~) of ions emitted in an electrospray (ESI) source interfaced with a sector mass spectrometer is evaluated by using the experimental survival yield (SY) method including the kinetic shift. This method is based on the relationship between t

A high resolving power ion selector for
✍ C. K. G. Piyadasa; P. HΓ₯kansson; T. R. Ariyaratne; D. F. Barofsky πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 156 KB πŸ‘ 2 views

An electrostatic deflector has been designed and constructed that can be used in a reflecting time-of-flight mass spectrometer for either single-deflector or dual-deflector velocity selection in post-source decay measurements. The deflector consists of an interleaved set of parallel deflection elect

Comparison of Tandem Mass Spectrometric
✍ G. Kopf; J. V. Headley; K. M. Peru; R. C. Johnson; M. H. Soni; R. G. Cooks πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 156 KB πŸ‘ 2 views

The herbicide, methyl 2-4-(2,4-dichlorophenoxy)phenoxy proprionate (diclofop-methyl), and three of its degradation products are identified in biofilm using tandem mass spectrometry (MS/MS). Sub-samples of a biofilm cultured in a flow-through system, with the herbicide diclofop-methyl in the nutritiv