Perfusion and diffusion MR imaging
✍ Scribed by M. D. King; N. Van Bruggen; A. L. Busza; J. Houseman; S. R. Williams; D. G. Gadian
- Publisher
- John Wiley and Sons
- Year
- 1992
- Tongue
- English
- Weight
- 857 KB
- Volume
- 24
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Diffusion‐weighted images of the rat brain were obtained using the pulsed‐gradient spinecho method. An attempt was made to extract perfusion‐related parameters from signal intensity data taken from the caudate‐putamen region of the images, by using a nonlinear least‐squares calculation to fit the Le Bihan biexponential expression (Le Bihan et al., Radiology, 168, 497 (1988)) to the data. The perfusion‐related parameters could not be obtained with sufficient accuracy to be useful, although the perfusion‐weighted images appear to contain meaningful qualitative information. An analysis of the perfusion model is presented and shows why the Le Bihan pseudo‐diffusion coefficient is particularly difficult to measure with reasonable accuracy. © 1992 Academic Press, Inc.
📜 SIMILAR VOLUMES
## Abstract __In vivo__ echo‐planar MR imaging was used to measure apparent diffusion coefficients (ADC) of cerebral tissues in a comprehensive noninvasive evaluation of early ischemic brain damage induced by occlusion of the middle cerebral artery (MCA) in a cat model of acute regional stroke. Wit
Temporary focal ischaemia was induced in wild-type C57Black/6 mice by thread occlusion of the middle cerebral artery (MCA). Recirculation was started after 60 min and maintained for 24 h, after which the mouse brain was frozen in situ. Development of the cerebral infarct was monitored by diffusion-,
## Abstract To monitor changes of brain tissue metabolism in acute demyelinating encephalitis (ADEM), we examined a patient with suspected ADEM by serial MRI including diffusion‐ and perfusion‐weighted imaging (DWI, PWI). Within the inflammatory tissue, the apparent diffusion coefficients were redu
## Abstract Use of the Stejskal‐Tanner sequence for performing diffusion images in the human brain tends to be complicated by the presence of artifacts caused by voluntary or involuntary, sometimes pulsatile, motion. We describe the implementation of the technique of echo‐planar diffusion imaging,
## Abstract The purpose of this study was to present the prebolus technique for quantitative multislice myocardial perfusion imaging. In quantitative MR perfusion studies the maximum contrast agent dose is limited by the requirement to determine the arterial input function (AIF). The prebolus techn