𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Orthogonal injection of matrix-assisted laser desorption/ionization ions into a time-of-flight spectrometer through a collisional damping interface

✍ Scribed by A. N. Krutchinsky; A. V. Loboda; V. L. Spicer; R. Dworschak; W. Ens; K. G. Standing


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
393 KB
Volume
12
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


Ions are produced from a conventional matrix-assisted laser desorption/ionization (MALDI) target by irradiation with a nitrogen laser pulsed at 20 Hz. After being cooled by collisions in an RF-quadrupole ion guide, the ions enter an orthogonal-injection TOF mass spectrometer, already used for electrospray. The collisional cooling spreads the ions out along the axis of the quadrupole to produce a quasi-continuous beam, which is then pulsed into the mass spectrometer at a repetition rate of about 4 kHz. Approximately five ions enter the mass spectrometer with each injection pulse, and these are detected using single-ion counting and registered in a TDC with 0.5 ns resolution.

The performance of the instrument is similar to that obtained with an ESI source. A uniform mass resolution of about 5000 (full width at half maximum definition) is routinely obtained for molecular weights up to about 6000 Da, with mass accuracy around 30 ppm. The sensitivity for peptides is in the low femtomole range. The mass range is currently limited by the low energy (5 keV) of the ions at the detector, although ions of cytochrome C (12 359 Da) have been detected.

The performance of the instrument for peptides is competitive with delayed-extraction MALDI in the usual axial geometry, but with the advantage of mass-independent focusing conditions, and a simple twopoint calibration procedure. However, the most important advantages result from the nearly complete decoupling of the ion production from the mass measurement. In the usual MALDI experiment the instrument must be carefully adjusted for optimum performance, and the optimum parameters depend on the matrix and the method of sample preparation. As a result of the decoupling, the performance of the instrument is independent of source conditions. This allows much greater flexibility to experiment with different matrices, different substrates (including insulating substrates), and different laser wavelengths, pulse widths and fluences.

Because of the decoupling, the design also allows convenient use of both ESI and MALDI sources (and possibly others) on the same spectrometer.


πŸ“œ SIMILAR VOLUMES


A high resolving power multiple reflecti
✍ C. K. G. Piyadasa; P. HΓ₯kansson; T. R. Ariyaratne πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 93 KB πŸ‘ 2 views

Two electrostatic mirrors, mounted symmetrically on the same optical axis facing each other, are used to increase the time-of-flight of molecular ions produced in matrix-assisted laser desorption/ionization (MALDI). The mirrors, which are used in the non-compensating mode, are located between a MALD

Using a matrix-assisted laser desorption
✍ Pfeifer, Thomas; Drewello, Mario; Schierhorn, Angelika πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 178 KB πŸ‘ 2 views

Mass spectrometric experiments with fragment ions have not yet been possible with a matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometer because intense signals of fragment ions were rarely observed during continuous extraction and the mass resolution of in-source

Profile and Flight Time Analysis of Bovi
✍ Kinsel, Gary R.; Edmondson, Ricky D.; Russell, David H. πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 361 KB πŸ‘ 1 views

Detailed ion signal proÐle and Γ‘ight time analyses were performed on the time-of-Γ‘ight signals obtained for bovine insulin cluster ions produced by matrix-assisted laser desorption/ionization (MALDI). ProÐle analyses of the ion signals strongly suggest that the signals are made up of a composite of