High-resolution Infrared Laser Desorption/Ionization and Matrix-assisted
A high resolving power multiple reflection matrix-assisted laser desorption/ionization time-of-flight mass spectrometer
✍ Scribed by C. K. G. Piyadasa; P. Håkansson; T. R. Ariyaratne
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 93 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
✦ Synopsis
Two electrostatic mirrors, mounted symmetrically on the same optical axis facing each other, are used to increase the time-of-flight of molecular ions produced in matrix-assisted laser desorption/ionization (MALDI). The mirrors, which are used in the non-compensating mode, are located between a MALDI ion source and a stop detector. The source is operated at 10.5 kV acceleration voltage using the delayed extraction technique. The high voltage for the mirror arrangement is switched on after the desorption event when the molecular ions have drifted into the region between the mirrors. The ions are trapped by successive reflections of the opposite electrostatic fields in the mirrors until the electric fields are switched off. The number of reflections depends on the speed of the ions when they enter the mirror trap and the ontime of the mirrors. When the electric fields are removed during the motion of the ions towards the stop detector, the ions penetrate the grids of the mirror and reach that detector. The extension of the flight path due to the number of reflections is used to increase the resolving power in time-of-flight spectra. Values of 55 000 for substance-P (MW 1346.7) and 31 000 for bovine insulin (MW 5734) were obtained for single laser shot spectra.
📜 SIMILAR VOLUMES
The ionization of nucleosides in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was systematically investigated using adenine (A), thymine (T), guanine (G) and cytosine (C) with several common matrices. Experimental results of the protonation and deprotonation of the ba
The time-of-flight effect in Fourier transform mass spectrometry (FTMS) with an external ion source was quantified. The time-of-flight profiles of ions of different masses were measured by stepping the time interval between the ionization pulse and the gating of the trapping voltage (T gate ). The o
We have developed a method for constructing and extracting matrix-assisted laser desorption/ionization (MALDI) fingerprints. This method is fully automated and statistically based, allowing a large number of spectra to be analyzed at a time in an objective manner. This method can be used to extract
The application of laser desorption/ionization and matrix-assisted laser desorption/ionization mass spectrometry to the study of the structure of some conducting polymers was investigated. A methodology was developed and the experimental conditions for the characterization of these polymers were est