## Matrix -assisted laser desorption/ionization (MALDI) mass spectrometry (MS) of oligosaccharides and polysaccharides has been investigated in detail. It is demonstrated that cationized species of oligosaccharides, [MNa] and [MK] , are dominant products under the MALDI condition, and negative ion
Organic ion imaging of biological tissue with secondary ion mass spectrometry and matrix-assisted laser desorption/ionization
✍ Scribed by Peter J. Todd; T. Gregory Schaaff; Pierre Chaurand; Richard M. Caprioli
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 787 KB
- Volume
- 36
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.153
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Organic secondary ion mass spectrometry (SIMS) and matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry can be used to produce molecular images of samples. This is achieved through ionization from a clearly identified point on a flat sample, and performing a raster of the sample by moving the point of ionization over the sample surface. The unique analytical capabilities of mass spectrometry for mapping a variety of biological samples at the tissue level are discussed. SIMS provides information on the spatial distribution of the elements and low molecular mass compounds as well as molecular structures on these compounds, while MALDI yields spatial information about higher molecular mass compounds, including their distributions in tissues at very low levels, as well as information on the molecular structures of these compounds. Application of these methods to analytical problems requires appropriate instrumentation, sample preparation methodology, and a data presentation usually in a three‐coordinate plot where x and y are physical dimensions of the sample and z is the signal amplitude. The use of imaging mass spectrometry is illustrated with several biological systems. Copyright © 2001 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
The ion formation and fragmentation of sinapinic acid, which is a typical matrix material for matrix-assisted laser desorption/ionization (MALDI), have been investigated by using electron ionization @I), liquid secondary ion (LSI) and MALDI methods. Collisionally activated dissociation (CAD) spectra
## Abstract Atmospheric pressure (AP) matrix‐assisted laser desorption/ionization (MALDI) is known to suffer from poor ion transfer efficiencies as compared to conventional vacuum MALDI (vMALDI). To mitigate these issues, a new AP‐MALDI ion source utilizing a coaxial gas flow was developed. Nitroge
The mechanisms of ion formation in matrix-assisted laser desorption/ionization mass spectrometry are still largely unknown. Ions may exist as pre-formed species in the solid state, or may form by ion-molecule reactions initiated by the laser shot, or, most probably, they may originate from a combina
Transition metal ion complexes with proteins and peptides are important in many areas of analytical and biological chemistry. We used positive and negative ion MALDI-MS to detect complexes with Cu and Ni ions, and show that the speciÐc and non-speciÐc transition metal ion-peptide complexes can be di
## Abstract Time‐of‐flight secondary ion mass spectrometry (TOF‐SIMS) using liquid metal ion guns (LMIGs) is now sensitive enough to produce molecular‐ion images directly from biological tissue samples. Primary cluster ions strike a spot on the sample to produce a mass spectrum. An image of this sa