During the control of a multistep organic synthesis on a soluble polymer (PEG) by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry, a chemical reactivity was encountered when the matrix was acidic, for the samples where the amino moiety of the anchored compounds was protected as
Inline pneumatically assisted atmospheric pressure matrix-assisted laser desorption/ionization ion trap mass spectrometry
✍ Scribed by Arti T. Navare; Facundo M. Fernández
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 347 KB
- Volume
- 45
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1749
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Atmospheric pressure (AP) matrix‐assisted laser desorption/ionization (MALDI) is known to suffer from poor ion transfer efficiencies as compared to conventional vacuum MALDI (vMALDI). To mitigate these issues, a new AP‐MALDI ion source utilizing a coaxial gas flow was developed. Nitrogen, helium, and sulfur hexafluoride were tested for their abilities as ion carriers for a standard peptide and small drug molecules. Nitrogen showed the best ion transport efficiency, with sensitivity gains of up to 1900% and 20% for a peptide standard when the target plate voltage was either continuous or pulsed, respectively. The addition of carrier gas not only entrained the ions efficiently but also deflected background species and declustered analyte–matrix adducts, resulting in higher absolute analyte signal intensities and greater signal‐to‐noise (S/N) ratios. With the increased sensitivity of pneumatically assisted (PA) AP‐MALDI, the limits of detection of angiotensin I were 20 or 3 fmols for continuous or pulsed target plate voltage, respectively. For analyzing low‐mass analytes, it was found that very low gas flow rates (0.3–0.6 l min^−1^) were preferable owing to increased fragmentation at higher gas flows. The analyte lability, type of gas, and nature of the extraction field between the target plate and mass spectrometer inlet were observed to be the most important factors affecting the performance of the in‐line PA‐AP‐MALDI ion source. Copyright © 2010 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
The protein content of several cow milks was investigated by matrix-assisted laser desorptionhonization (MALDI) mass spectrometry. In particular, milk from four dinerent breeds of cow (Holstein Frisons, Brown Swiss, Jersey and Reggiana) at the same lactation stage and under the same feeding system w
## Abstract The application of matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) for quantitative analysis was investigated with the use of internal standards. Three peptides/proteins in the mass range 1000–12000 were tested and the effect of various internal standards was ev
## Matrix -assisted laser desorption/ionization (MALDI) mass spectrometry (MS) of oligosaccharides and polysaccharides has been investigated in detail. It is demonstrated that cationized species of oligosaccharides, [MNa] and [MK] , are dominant products under the MALDI condition, and negative ion
The mechanisms of ion formation in matrix-assisted laser desorption/ionization mass spectrometry are still largely unknown. Ions may exist as pre-formed species in the solid state, or may form by ion-molecule reactions initiated by the laser shot, or, most probably, they may originate from a combina