๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

On the recovery of the electroretinogram of rats after removal of intravitreal lead particles

โœ Scribed by Joachim G. H. Schmidt; Elmar W. G. Ehring


Book ID
104673386
Publisher
Springer-Verlag
Year
1986
Tongue
English
Weight
488 KB
Volume
62
Category
Article
ISSN
0012-4486

No coin nor oath required. For personal study only.

โœฆ Synopsis


Lead particles (1.4 mm2) were implanted into the vitreous body of rats (16 animals) for 10 days and the recovery rate of the ERG was measured over an observation time of 190 days. After extraction of the lead particles the a- and b-wave amplitudes show a recovery from about 60% to 87% in comparison to those of the intact fellow eyes between the 60th and 90th day of observation. In earlier experiments the mechanical damage was measured using glass splinters. The differences between these values and the above mentioned recovery rate after lead extraction correspond to the irreversible component of the metal intoxication. In another group of rats (16 animals) the lead particle was not removed before the end of the observation time of 190 days. Subtracting these ERG values from those of the first group of rats after lead extraction one gets small differences which correspond to the reversible component of the metal intoxication. The irreversible lead intoxication is much less than that of intravitreal iron particles as we found under the same conditions. The lead particles we used, are larger than those we have to handle in clinical cases taking the relation of surface area size of the particle to the total bulbus weight. The ophthalmoscopical findings are described.


๐Ÿ“œ SIMILAR VOLUMES


On the recovery of the electroretinogram
โœ Joachim G. H. Schmidt; Regina Mansfeld-Nies; Christoph Nies ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› Springer-Verlag ๐ŸŒ English โš– 426 KB

This report details the influence of the time lapse and surface area size of intravitreal copper foreign bodies on the etectroretinogram (ERG) and the recovery of the potentials after removal of the particles. Pure copper wires were implanted temporarily into the vitreous body of rat eyes in the are

On the recovery of the electroretinogram
โœ Joachim G. H. Schmidt; Christoph Nies; Regina Mansfeld-Nies ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› Springer-Verlag ๐ŸŒ English โš– 474 KB

The influence of intravitreal zinc particles (1.3 mm 2) in the eyes of rats caused the amplitudes of the electroretinogram to decrease to about 50% of the initial values within 24 hours, whereas the prolongation of the peak times began only on the third day after particle implantation. The removal o

Surface area sizes of intravitreal iron
โœ Joachim G. H. Schmidt; Michael Max ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› Springer-Verlag ๐ŸŒ English โš– 472 KB

The electroretinogram (ERG) was recorded 20 times over a period of 360 days in 26 albino-rats with implanted intravitreal iron wires ranging in size between 0.15 and 1.2 mm 2. Results: (i) The a-and b-wave amplitudes decreased rapidly within one day after iron wire implantation. During the following