A method for the determination of isotopic composition by combined gas chromatography-combustion-isotope ratio mass spectrometry was examined in order to measure the stable carbon isotope ratios of methane and carbon monoxide in environmental samples. The factors causing deviations in the observed v
On-line purification and carbon-13 isotopic analysis of carbon dioxide in breath: evaluation of on-line gas chromatography-isotope ratio mass spectrometry
✍ Scribed by R. Guilluy; F. Billion-Rey; C. Pachiaudi; S. Normand; J.P. Riou; E.J. Jumeau; J.L. Brazier
- Publisher
- Elsevier Science
- Year
- 1992
- Tongue
- English
- Weight
- 831 KB
- Volume
- 259
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
✦ Synopsis
An on-hne gas chromatograpluc-isotope ratlo mass spectrometrlc (IRMS) device consisting of a gas chromatograph, a column swltchmg system, a continuous-flow dual Inlet and an isotope ratlo mass spectrometer IS described This device has been found s&able for the simultaneous on-hne punficatlon of expired breath CO, and the determmatlon of Its rsotoplc cornposItIon The quahty of the analytical data obtamed vahdated the clm& use of the method to perform breath tests at low enruzhment levels and from small samples The whole procedure 1s rehable, simple and efficient It IS capable of analysmg breath samples down to 50 gl wthm 150 s Its high rehablhty and advantages over the conventional IRMS techmque are &cussed
📜 SIMILAR VOLUMES
Micro LC analysis of the six major hop bitter acids with corresponding UV-spectrum. Retention time of last eluting compound = 48 min.
Isotope ratio monitoring gas chromatography-mass spectrometry of the 2 H/ 1 H ratio by pyrolysis isotope ratio mass spectrometry (P-IRMS) was used to analyze benzaldehyde originating from various sources. Based on the d 2 H SMOW value of an authentic reference sample determined with an elemental ana
## Abstract Based on ^2^H/^1^H measurements of commercial synthetic and natural citral (neral and geranial), on‐line gas chromatography–pyrolysis–isotope ratio mass spectrometry (HRGC–P–IRMS) was used to determine the δ^2^H~SMOW~ values of citral in essential oils from __Cymbopogon flexuosus__ and
An isotope ratio mass spectrometer and an ion trap mass spectrometer have been coupled in parallel to one gas chromatograph. Using this arrangement both the 13C/12C ratio and the mass spectrum of a given compound can be measured simultaneously under identical gas chromatographic conditions. Although