Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is shown to give inaccurate results for the analysis of low molecular weight ethoxylate polymers. It is demonstrated that when the degree of ethoxylation is low (n < 9), MALDI-TOFMS produces substantially high
Novel Procedure for Molecular Weight Averages Measurement of Polydisperse Polymers Directly from Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectra
โ Scribed by Giorgio Montaudo; Emilio Scamporrino; Daniele Vitalini; Placido Mineo
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 650 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
โฆ Synopsis
A new method for the determination of reliable molecular weight averages (MW) and polydispersity index (MWD) values for polydisperse polymers, directly analyzing their matrix-assisted laser/desorption ionization time-of-flight (MALDI-TOF) mass spectra, is reported. Our success is due to the concerted effect of an off-line procedure of MALDI-TOF spectrum processing that includes: (i) signal smoothing to improve the recorded traces of the spectra up to high m/z values; (ii) a subtraction of the misleading contribution to the signals introduced by the offset used in spectrum recording; (iii) examination of the spectrqup to the highest possible m/z value for a better accuracy in estimating the MW values. To illustrate this method, three polymers with a wide polydispersity index, a polydimethylsiloxane, a polymethylmethacrylate, and a bisphenol-A copolyether, have been analyzed. Contrary to the general opinion that MW values can be measured directly by MALDI-TOF only for polymers with a very narrow mass distribution, the data reported here show that our off-line procedure is also able to measure reliable MW values for polydisperse materials.
๐ SIMILAR VOLUMES
The determination of molecular mass (MM) data for polydisperse polymers by size exclusion chromatography matrix assisted laser desorption/ionization time-of-flight (SEC/MALDI-TOF) involves the fractionation of samples through an analytical SEC. Selected fractions are then analysed by MALDI-TOF and t
Seven polystyrene molecular mass standards have been run in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) singly, in pairs, in groups of three and as a mixture of the seven distinct samples. All standards had polydispersities of near unity. When run singl
We recently demonstrated that the combined use of lipopolysaccharide (LPS) reverse staining and high-efficiency passive elution techniques can be successfully used as a suitable interface between LPS slab-gel separation and electrospray ionization-mass spectrometry (ESI-MS) of LPS-derived oligosacch