Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is shown to give inaccurate results for the analysis of low molecular weight ethoxylate polymers. It is demonstrated that when the degree of ethoxylation is low (n < 9), MALDI-TOFMS produces substantially high
Effect of polydispersity on the characterization of coal-derived liquids by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry: inferences from results for mixtures of polystyrene molecular mass standards
β Scribed by Mark Domin; R. Moreea; M.-J. Lazaro; Alan A. Herod; Rafael Kandiyoti
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 170 KB
- Volume
- 11
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
Seven polystyrene molecular mass standards have been run in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) singly, in pairs, in groups of three and as a mixture of the seven distinct samples. All standards had polydispersities of near unity. When run singly or in pairs, MALDI-spectra of all standard polymer samples could be observed clearly and showed approximately equal areas. Mixtures of multiple standards have been run at variable ion extraction voltages: when the voltage was reduced below 25 kV, low molar mass samples tended to predominate in the spectra, at the expense of the higher molar mass standards. Peaks due to the high mass standards were still observable above the noise level, but (for equimolar mixtures) areas under the peaks were no longer comparable. With the full set of seven samples, discrimination against intensities of the higher mass standards could be clearly observed, even at the highest ion extraction voltage available (30 kV). With increasing ion extraction voltage the MALDI-spectra of a coal tar pitch and its tetrahydrofuran-insoluble fraction showed increasing intensities of higher mass ranges. Due to the wide polydispersity of coal derived samples, MALDI-spectra would be expected to severely underestimate the proportion of high mass materials present. Further work on mixtures of different types of polymer standards would clearly be useful; for coal derived liquids, more extensive fractionation than that used here would seem advisable in order to reduce sample polydispersity.
π SIMILAR VOLUMES
## Very little work has been done on exploring the transition metals as suitable cationizing agents for the analysis of polymers by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF ). This paper reports on the characterization of polystyrenes and polyethylene glycols with sele
Fundamental concepts of high-resolution mass spectrometry as it relates to the issue of accurate mass measurements are presented. Important issues speciΓc to magnetic sector instruments, Fourier transform ion cyclotron resonance and time-of-Γight (TOF) methods are discussed. Recent high-resolution T
Data reported here show that, in the delayed extraction matrix-assisted laser desorption/ionization time-offlight (DE-MALDI-TOF) mass spectrometric analysis of synthetic polydisperse polymers, different experimental conditions of spectral recording are required to optimize the signal in all the m/z
The increased interest in spider venom toxins has made precise identification of venom samples necessary for reproducibility of biochemical and pharmacological studies. In the family Theraphosidae (Tarantulas), identification of specimens may be difficult and a new approach involving multidimensiona