𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Multiple field strength in vivo T1 and T2 for cerebrospinal fluid protons

✍ Scribed by A. L. Hopkins; H. N. Yeung; C. B. Bratton


Publisher
John Wiley and Sons
Year
1986
Tongue
English
Weight
548 KB
Volume
3
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


To estimate the feasibility of measuring in vivo CSF protein, oxygen, or other solutes through their effect on proton relaxation times, the TI and T2 of CSF protons has been measured within the human lateral ventricles. T I was measured at 6.25, 25.4, and 60.1 MHz with a two-point method. T, was measured at 6.25 and 25.4 MHz using the CPMG sequence to acquire 8 echo images. The T I was 4.3 s with no evidence of field dependence. The T2 was 2 s. Although these values approach those for water at the same temperature it is possible that the T I is influenced by the normal oxygen concentration. Calculations based on the relaxivity of dissolved protein indicate that the use of these methods for the detection of elevated levels of CSF protein would be less sensitive than existing methods.


πŸ“œ SIMILAR VOLUMES


High magnetic field water and metabolite
✍ Robin A. de Graaf; Peter B. Brown; Scott McIntyre; Terence W. Nixon; Kevin L. Be πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 612 KB

## Abstract Comprehensive and quantitative measurements of __T__~1~ and __T__~2~ relaxation times of water, metabolites, and macromolecules in rat brain under similar experimental conditions at three high magnetic field strengths (4.0 T, 9.4 T, and 11.7 T) are presented. Water relaxation showed a h

In vivo determination of T1 and T2 in th
✍ H. B. W. Larsson; J. Frederiksen; L. KjΓ¦r; O. Henriksen; J. Olesen πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 600 KB

In vivo measurements of relaxation processes in multiple sclerosis (MS) lesions by magnetic resonance imaging (MRI) may be important for evaluation of the disease activity in individual MS plaques. To obtain information of presumably chronic plaques, 10 patients with severe, but stable MS were inves

In vivo evaluation of the reproducibilit
✍ H.B.W. Larsson; P. Christiansen; I. Zeeberg; O. Henriksen πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 661 KB

The precision (reproducibility) of relaxation times derived from magnetic resonance images of patients with multiple sclerosis (MS) were investigated. Measurements of 10 MS patients were performed at 1.5 T on two occasions within 1 wk. T1 and T2 was measured using a partial saturation inversion reco

In Vivo Brain Water Determination by T1
✍ P. P. Fatouros; A. Marmarou; K. A. Kraft; S. Inao; F. P. Schwarz πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 650 KB

This work is concerned with the accurate quantification of brain water content under routine clinical conditions. Gelatin solutions of varying water content are first employed as a model of an edematous brain and longitudinal relaxation measurements are performed at proton Larmor frequencies of 5, 4

Measurement of in vivo multi-component T
✍ Joonmi Oh; Eric T. Han; Daniel Pelletier; Sarah J. Nelson πŸ“‚ Article πŸ“… 2006 πŸ› Elsevier Science 🌐 English βš– 789 KB

The objective of this study was to implement a clinically relevant multi-slice multi-echo imaging sequence in order to quantify multicomponent T2 relaxation times for normal volunteers at both 1.5 and 3 T. Multi-echo data were fitted using a nonnegative least square algorithm. Twelve echo data with