𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Molecular distribution of some commercial nonylphenol ethoxylates using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

✍ Scribed by F. O. Ayorinde; B. E. Eribo; J. H. Johnson Jr.; E. Elhilo


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
90 KB
Volume
13
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


Nonylphenol ethoxylates (NPEs) belong to a group of nonionic surfactants that are collectively referred to as alkylphenol ethoxylates (APEs). APEs find widespread use in heavy-duty commercial and household cleaning formulations, shampoos, and industrial processing, i.e. textile manufacture. Their environmental impact depends on the molecular distribution and the extent of their biodegradation in municipal sewage systems, waterways and rivers. We have established two sample preparation methods that have enabled the determination of the molecular distributions of six commercial nonylphenol ethoxylates using matrixassisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS). In both methods, a-cyano-4-hydroxycinnamic acid, dissolved in acetonitrile/tetrahydrofuran, was used as the matrix. In one set of experiments, the NPEs were dissolved in an acetonitrile/tetrahydrofuran solvent system prior to mixing with the matrix solution, and the resulting MALDI-TOF mass spectra produced mostly sodiated molecules [M Na] . The NPEs, all having the formula 4-(C 9 H 19 )-C 6 H 4 -(OCH 2 CH 2 ) n -OH, are Surfonic 1 N-95, N-100, N-102, N-120, N-150 and N-300. Surfonic N-95 and N-100 gave n values of 5-20; Surfonic N-102, N-120, N-150, and N-300 gave n values of 5-21, 5-22, 8-25 and 15-40, respectively. In order to develop a sample preparation method that could be used with less polar NPEs, we dissolved the NPEs (except N-300) in pentane prior to mixing with the matrix solution, and found that the MALDI spectral quality was unaffected by the solvent systems.


πŸ“œ SIMILAR VOLUMES


Determination of the instrumental detect
✍ Folahan O. Ayorinde; Eisa Elhilo πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 172 KB πŸ‘ 1 views

Recent interest in the environmental fate and impact of nonylphenol ethoxylates (NPEs) has necessitated the need for the development of specific, and yet efficient, analytical methodologies for their detection. Using seventeen commercial NPEs, all having the general formula 4-(C(9)H(19))-C(6)H(4)-(O

Ionization mechanism of oligonucleotides
✍ Yufei Kong; Yifei Zhu; Jing-Yuan Zhang πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 171 KB πŸ‘ 2 views

The ionization of nucleosides in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was systematically investigated using adenine (A), thymine (T), guanine (G) and cytosine (C) with several common matrices. Experimental results of the protonation and deprotonation of the ba

Sequencing of a branched peptide using m
✍ I. Fournier; P. Chaurand; G. Bolbach; F. LΓΌtzenkirchen; B. Spengler; J. C. Tabet πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 163 KB πŸ‘ 1 views

Chemical degradation methods combined with matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and post-source decay (PSD)-MALDI reflex TOF mass spectrometry (MS) were used to determine the sequence of a peptide branched on to a known peptide backbone. This study was applied to a

Differentiation of enantiomers using mat
✍ M. P. So; T. S. M. Wan; T.-W. Dominic Chan πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 54 KB πŸ‘ 2 views

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has successfully been used to differentiate pseudo-enantiomeric (isotopically labelled) amino acids by using cyclodextrin as complexing host. By using different pseudo-enantiomeric mixtures (i.e. R Dn S; and R S Dn ), it has be

Time-of-flight effects in matrix-assiste
✍ T.-P. E. Sze; T.-W. Dominic Chan πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 137 KB πŸ‘ 2 views

The time-of-flight effect in Fourier transform mass spectrometry (FTMS) with an external ion source was quantified. The time-of-flight profiles of ions of different masses were measured by stepping the time interval between the ionization pulse and the gating of the trapping voltage (T gate ). The o