Nonylphenol ethoxylates (NPEs) belong to a group of nonionic surfactants that are collectively referred to as alkylphenol ethoxylates (APEs). APEs find widespread use in heavy-duty commercial and household cleaning formulations, shampoos, and industrial processing, i.e. textile manufacture. Their en
Determination of the instrumental detection limits of commercial nonylphenol ethoxylates with a wide range of molecular masses using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
β Scribed by Folahan O. Ayorinde; Eisa Elhilo
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 172 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
Recent interest in the environmental fate and impact of nonylphenol ethoxylates (NPEs) has necessitated the need for the development of specific, and yet efficient, analytical methodologies for their detection. Using seventeen commercial NPEs, all having the general formula 4-(C(9)H(19))-C(6)H(4)-(OCH(2)CH(2))(n)-OH, we have established minimum concentrations at which matrix-assisted laser desorption ionization (MALDI)/time-of-flight (TOF)/mass spectrometry (MS) can be used in their detection. The NPEs were dissolved in an acetonitrile/tetrahydrofuran (3:1) solvent system prior to mixing with the matrix (alpha-cyano-4-hydroxycinnamic acid, dissolved in acetonitrile/tetrahydrofuran) solution, and the resulting MALDI-TOF mass spectra produced mostly sodiated molecules M + Na.For the NPEs in which the major components contain three to ten ethoxy units, the sodiated molecules were detected at a minimum analyte concentration of 10 &mgrg/L, whereas those in which the major components contain eight to fifteen ethoxy units were detected at a minimum concentration of 30 &mgrg/L. Those NPEs containing oligomers in excess of twenty ethoxy units were only detectable at much higher concentration. For examples, Surfonic(R) N-300, N-400, N550, N-700, N-800, and N-1000 had detection limits of (&mgrg/L): 1000, 1600, 2000, 2600, 3500 and 4500, respectively. These variations in instrumental detection limits must be considered when analyzing environmental samples for the presence of nonylphenol ethoxylates. Copyright 1999 John Wiley & Sons, Ltd.
π SIMILAR VOLUMES
Chemical degradation methods combined with matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and post-source decay (PSD)-MALDI reflex TOF mass spectrometry (MS) were used to determine the sequence of a peptide branched on to a known peptide backbone. This study was applied to a
The application of matrix-assisted laser desorption time-of-flight mass spectrometry for the analysis of silsesquioxanes is demonstrated. Several matrices have been tested for their utility in combination with a UV-laser based system, of which 2,5-dihydroxybenzoic acid provided the best signal to no
Five specialty oils; flaxseed, walnut, sesame, grapeseed and hazelnut, have been analyzed by matrix-assisted laser desorption ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS). a-Cyano-4hydroxycinnamic acid, dissolved in acetonitrile/tetrahydrofuran, was used as the matrix. The MALDI-TO
A method using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) for the determination of the fatty acid composition of vegetable oils is described and illustrated with the analysis of palm kernel oil, palm oil, olive oil, canola oil, soybean oil, vernonia oi