The combination of packed fused silica columns and the laser light- scattering detector has been examined. A column, 10 cm x 0.32 mm i.d., packed with a 4-pm C,, material, was mounted in a drift tube that functioned as a column oven. The restrictor was positioned in the detector cell. Standard curve
Miniaturized light scattering detector for packed capillary supercritical fluid chromatography
β Scribed by M. Demirbuker; P. E. Anderson; L. G. Blomberg
- Publisher
- John Wiley and Sons
- Year
- 1993
- Tongue
- English
- Weight
- 525 KB
- Volume
- 5
- Category
- Article
- ISSN
- 1040-7685
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Packed capillary columns provide excellent separation of neutral lipids by supercritical fluid chromatography. For these separations, it is necessary to add a polar modifier to the mobile phase; hitherto, a detector suitable for quantitative analysis has been lacking. For this purpose, a miniaturized evaporative light scattering detector for combination with packed microcolumns in supercritical fluid chromatography has been developed. Since the detector response is dependent on the mobile phase flow rate, a drop in response was found at flow rates above 16 mL min^β1^ of expanded mobile phase. However, below this flow rate, there was a region of relatively constant response. In this region, quantitative analysis could also be successfully performed when the pressure and/or the temperature of the separation were programmed. The detection limit was lower than 6 ng. With pressure programming, the relative standard deviation in peak area was less then 4%. Minor peaks gave higher RSD values.
Further, it is demonstrated that argentation SFC of triacylglycerols provides separation according to chain length as well as to the degree of unsaturation.
π SIMILAR VOLUMES
A miniaturized evaporative light scattering detector ELSD compatible Ε½ . with packed microcolumn high-performance liquid chromatography HPLC has been developed. In such a detector, it is particularly important that an efficient nebulization of the column effluent is achieved. Therefore, the geometry