Packed capillary supercritical fluid chromatography with mixed mobile phases and light-scattering detection
β Scribed by Stephan Hoffmann; Tyge Greibrokk
- Publisher
- John Wiley and Sons
- Year
- 1989
- Tongue
- English
- Weight
- 464 KB
- Volume
- 1
- Category
- Article
- ISSN
- 1040-7685
No coin nor oath required. For personal study only.
β¦ Synopsis
The combination of packed fused silica columns and the laser light- scattering detector has been examined. A column, 10 cm x 0.32 mm i.d., packed with a 4-pm C,, material, was mounted in a drift tube that functioned as a column oven. The restrictor was positioned in the detector cell. Standard curves and slopes were obtained for 5-60 ng of trimyristin and Irgafos-168 with 2.9 and 5.6 mol % of n-propanol in carbon dioxide. With pressure programming at a constant modifier concentration, the relative standard deviations in peak areas were determined to be less than 4%, except for the 5-ng injections. The reproducibility of retention times was better than 0.5%. Two applications are demonstrated.
π SIMILAR VOLUMES
## Abstract The eluotropic strength of several hydrofluorocarbon and perfluorocarbon supercritical fluids is examined using capillary supercritical fluid chromatography. The results obtained are compared with carbon dioxide, fluoroform, and carbon dioxide modified with 5% methanol. Various naphthal
A versatile system with a slurry-packed capillary column was developed for supercritical fluid chromatography, which is capable of programming both inlet and outlet pressure independently, as well as using a restrictor to apply back pressure. This system revealed the relationships between pressure d
A simple interface between a capillary supercritical fluid chromatograph and an Extranuclear Simulscan mass spectrometer is described. The SFC column is directly inserted into the ion source through the existing GC-interface. The system is equipped with a splitting device which allows simultaneous E
The useful combination of capillary supercritical fluid chromatography with ultraviolet multichannel detection is demonstrated by the analysis of selected pesticides and herbicides. In this application the advantages of compound identification by ultraviolet spectrometry are appended to theseparatin
## Abstract Neat water at temperatures above its normal boiling point was used as a mobile phase for packed capillary column chromatography. The βuniversalβ flame ionization detector (FID) was used for detection. No restrictor or back pressure was imposed at the column outlet. The effects of temper