𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Microparticle-enhanced nephelometric immunoassay for human C-reactive protein

✍ Scribed by Dr. P. Montagne; P. Laroche; M. L. Cuillière; P. Varcin; B. Pau; J. Duheille


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
565 KB
Volume
6
Category
Article
ISSN
0887-8013

No coin nor oath required. For personal study only.

✦ Synopsis


Polyfunctional hydrophilic microspheres of 125-nm diameter can be produced by copolymerization of acrylic monomers. Purified c-reactive protein (CRP) was covalently bound to these new micropheres, and the conjugate obtained was used as reagent in a microparticle-enhanced nephelometric immunoassay for human CR!? This assay was based on the measure, with a specially designed nephelometer, of the light scattered by aggregates formed during the immunoagglutination of the conjugate with anti-CRP antiserum. Sensitive inhibition of this agglutination by free CRP (6 ngiml) allowed CRP quantitation in highly diluted serum samples (1/500-1/2,000), excluding any interference or sample pretreatment. The CRP assay was easy to perform (no washing or phase separation), reliable (coefficients of variation ranged from 1.3% to 9.3% for within-run and between-run determinations), and accurate (mean percentage of recovery: 104%; correlation coefficients with accepted analytical methods 20.97) over a large range of concentrations. The inhibition mode excluded errors in the antigen excess zone and provided total security at high concentrations.


📜 SIMILAR VOLUMES


Microparticle-enhanced nephelometric imm
✍ E. Marchal; P. Montagne; M. L. Cuillière; M. C. Béné; G. Faure 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 538 KB

A microparticle-enhanced nephelometric immunoassay was developed for plasminogen quantitation in human plasma. It is based on the nephelometric measurement of the light scattered by microparticle clusters formed during a sandwich reaction between plasminogen, microparticle-anti-plasmino- gen conjuga

Microparticle-enhanced nephelometric imm
✍ M. L. Cuillière; P. Montagne; C. Molé; M. C. Béné; G. Faure 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 54 KB

A microparticle-enhanced nephelometric immunoassay was developed for lactoferrin quantitation in human milk. It is based on the nephelometric measurement of the light scattered during the competitive immuno-agglutination of a microparticle-lactoferrin conjugate with an antilactoferrin antiserum. Thi

Development of a microparticle-enhanced
✍ M. Caballero; R. Ruiz; M. Márquez de Prado; M. Seco; L. Borque; J.F. Escanero 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 101 KB

A microparticle-enhanced nephelometric immunoassay, based on polystyrene beads coated with antihuman lysozyme antibody, has been developed for lysozyme quantification in sera and pleural effusions. The standard curve extends from 0.58 mg/l to 18.75 mg/l and no antigen effect was observed. The result

Development of a rapid microparticle-enh
✍ F. Cliquet; P. Montagne; M. L. Cuillière; P. Varcin; J. Duheille 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 533 KB

A microparticle-enhanced nephelometric immunoassay was developed for myoglobin quantitation in human serum. It uses rabbit antimyoglobin serum and hydrophilic polyacrylic microparticles covalently coated with baboon myoglobin in a competitive immunoagglutination system. The level of microparticle ag