𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Development of a microparticle-enhanced nephelometric immunoassay for quantitation of human lysozyme in pleural effusion and plasma

✍ Scribed by M. Caballero; R. Ruiz; M. Márquez de Prado; M. Seco; L. Borque; J.F. Escanero


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
101 KB
Volume
13
Category
Article
ISSN
0887-8013

No coin nor oath required. For personal study only.

✦ Synopsis


A microparticle-enhanced nephelometric immunoassay, based on polystyrene beads coated with antihuman lysozyme antibody, has been developed for lysozyme quantification in sera and pleural effusions. The standard curve extends from 0.58 mg/l to 18.75 mg/l and no antigen effect was observed. The results showed a good serial precision. The intra-assay precision (n = 20) expressed as CV was between 2.2 and 4.2 in three different concentrations. The interassay precision, with different calibration curves (n = 12) was between 6.4 and 7.1. The analytical assay showed a sufficient linearity (r > 0.999). There were no interfer-ences either with haemoglobin (up to 4 g/l), lipids (up to 0.5%, expressed as l% Lipofundina® content), or bilirubin (up to 5 mg/dl). The analytical sensitivity was lower than 0.6 mg/l. The correlation with a Micrococcus lysodeikticus turbidimetric assay showed a correlation coefficient of 0.915. We have studied 92 patients with pleural effusion. In each case, pleural fluid adenosine deaminase activity and pleural fluid to plasma lysozyme ratio were determined. The lysozyme ratio showed similar clinical sensitivity and specificity as to adenosine deaminase.


📜 SIMILAR VOLUMES


Development and validation of a highly s
✍ Kishore Kumar Hotha; D. Vijaya Bharathi; B. Jagadeesh; L. K. Ravindranath; K. N. 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 311 KB 👁 3 views

## ABSTRACT A highly sensitive, specific and simple LC‐MS/MS method was developed for the simultaneous estimation of dexlansoprazole (DEX) with 50 μL of human plasma using omeprazole as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under multiple reaction‐monitoring mode using elect

Development and validation of a liquid c
✍ Paraskevi Valavani; Julia Atta-Politou; Irene Panderi 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 191 KB 👁 1 views

## Abstract A method was developed and fully validated for the quantitation of prazepam and its major metabolites, oxazepam and nordiazepam, in human plasma. Sample pretreatment was achieved by solid‐phase extraction using Oasis HLB cartridges. The extracts were analysed by high‐performance liquid

Development and validation of a high-per
✍ Isabela Costa César; Ricardo Martins Duarte Byrro; Fabiana Fernandes de Santana 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 381 KB 👁 1 views

A sensitive and fast high-performance liquid chromatography-electrospray ionization-MS/MS method for the simultaneous quantitation of levodopa and carbidopa in human plasma was developed and validated. A simple protein precipitation step with perchloric acid was used for the cleanup of plasma, and m

Development and validation of a sensitiv
✍ D. Vijaya Bharathi; Kishore Kumar Hotha; P. V. Vidya Sagar; S. Sirish Kumar; A. 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 396 KB 👁 2 views

## Abstract A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of pramipexole (PPX) with 500 µL human plasma using memantine as an internal standard (IS). The API‐4000 was operated under multiple‐reaction monitoring mode (MRM) using the electrospray