Development and validation of a high-performance liquid chromatography–electrospray ionization–MS/MS method for the simultaneous quantitation of levodopa and carbidopa in human plasma
✍ Scribed by Isabela Costa César; Ricardo Martins Duarte Byrro; Fabiana Fernandes de Santana e Silva Cardoso; Iram Moreira Mundim; Leonardo de Souza Teixeira; Sandro Antônio Gomes; Ricardo Rodrigues Bonfim; Gerson Antônio Pianetti
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 381 KB
- Volume
- 46
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1973
No coin nor oath required. For personal study only.
✦ Synopsis
A sensitive and fast high-performance liquid chromatography-electrospray ionization-MS/MS method for the simultaneous quantitation of levodopa and carbidopa in human plasma was developed and validated. A simple protein precipitation step with perchloric acid was used for the cleanup of plasma, and methyldopa was added as an internal standard. The analyses were carried out using an ACE C(18) column (50 × 4.6 mm i.d.; 5 µm particle size) and a mobile phase consisting of 0.2% formic acid and acetonitrile (90:10). The triple-quadrupole mass spectrometer equipped with an electrospray source in positive mode was set up in the selective reaction monitoring mode to detect the ion transitions m/z 198.1 → m/z 107.0, m/z 227.2 → m/z 181.0, and m/z 212.1 → m/z 139.2 for levodopa, carbidopa, and methyldopa, respectively. The method was validated and proved to be linear, accurate, and precise over the range 50-5000 ng/mL for levodopa and 3-600 ng/mL for carbidopa. The proposed method was successfully applied in a pharmacokinetic study with a levodopa/carbidopa tablet formulation in healthy volunteers.
📜 SIMILAR VOLUMES
## Abstract A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of pramipexole (PPX) with 500 µL human plasma using memantine as an internal standard (IS). The API‐4000 was operated under multiple‐reaction monitoring mode (MRM) using the electrospray
## Abstract A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of torcetrapib (TTB) with 100 µL hamster/dog plasma using DRL‐16126 as an internal standard (IS). The API‐4000 Q Trap LC‐MS/MS was operated under multiple‐reaction monitoring mode using t
## Abstract A liquid chromatography/tandem mass spectrometry (LC‐MS/MS) method, characterized by complete automation and high‐throughput, was developed for the determination of colistin A and B in human plasma. All sample preparation procedures were performed by using 2.2 mL 96‐deep‐well plates, wh
## Abstract A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of doxofylline (DFL) with 300 µL human serum using imipramine as the internal standard (IS). The API‐3000 LC‐MS/MS was operated under multiple reaction‐monitoring mode using the electrosp