Development and validation of a sensitive LC-MS/MS method with electrospray ionization for quantitation of pramipexole in human plasma: application to a clinical pharmacokinetic study
✍ Scribed by D. Vijaya Bharathi; Kishore Kumar Hotha; P. V. Vidya Sagar; S. Sirish Kumar; A. Naidu; Ramesh Mullangi
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 396 KB
- Volume
- 23
- Category
- Article
- ISSN
- 0269-3879
- DOI
- 10.1002/bmc.1108
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of pramipexole (PPX) with 500 µL human plasma using memantine as an internal standard (IS). The API‐4000 was operated under multiple‐reaction monitoring mode (MRM) using the electrospray ionization technique. Solid‐phase extraction was used to extract PPX and IS from human plasma. The resolution of peaks was achieved with 0.01 m ammonium acetate buffer (pH 4.4):acetonitrile (30:70, v/v) on a Discovery CN column. The total chromatographic run time was 3.0 min and the elution of PPX and IS occurred at approximately 2.32 and 2.52, respectively. The MS/MS ion transitions monitored were 212.10 → 153.10 for PPX and 180.20 → 107.30 for IS. The method was proved to be accurate and precise at linearity range of 20–3540 pg/mL with a correlation coefficient (r) of ≥0.999. The intra‐ and inter‐day precision and accuracy values found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 0.25 mg PPX tablet. Copyright © 2008 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of doxofylline (DFL) with 300 µL human serum using imipramine as the internal standard (IS). The API‐3000 LC‐MS/MS was operated under multiple reaction‐monitoring mode using the electrosp
## ABSTRACT A highly sensitive, specific and simple LC‐MS/MS method was developed for the simultaneous estimation of dexlansoprazole (DEX) with 50 μL of human plasma using omeprazole as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under multiple reaction‐monitoring mode using elect
## Abstract A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of torcetrapib (TTB) with 100 µL hamster/dog plasma using DRL‐16126 as an internal standard (IS). The API‐4000 Q Trap LC‐MS/MS was operated under multiple‐reaction monitoring mode using t