𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Measurement of arterial plasma oxygenation in dynamic oxygen-enhanced MRI

✍ Scribed by Lucy E. Kershaw; Josephine H. Naish; Deirdre M. McGrath; John C. Waterton; Geoffrey J. M. Parker


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
564 KB
Volume
64
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Inhaled oxygen can be used as a contrast agent for magnetic resonance imaging, due to the T~1~ shortening effect of the oxygen dissolved in blood and tissue water. In this study, blood T~1~ was measured dynamically in 14 volunteers (seven smokers, seven never‐smokers) as the inhaled gas was switched from medical air to 100% oxygen and back to medical air. These T~1~ values were converted to changes in partial pressure of oxygen, which were found to be in agreement with literature values. There were differences in curve shape and curve height between the smoker and never‐smoker groups, suggesting differences in lung function due to smoking‐related damage. These curves could be used as an input function for modeling of oxygen uptake in tissues. The differences between groups highlight the importance of measuring such an input function for each individual rather than relying on an assumed measurement. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Dynamic oxygen-enhanced MRI reflects dif
✍ Yoshiharu Ohno; Hiroto Hatabu; Daisuke Takenaka; Marc Van Cauteren; Masahiko Fuj 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 411 KB

The purpose of this study was to demonstrate the feasibility of dynamic oxygen-enhanced MRI in a clinical setting. We hypothesized that dynamic oxygen enhancement can reflect the regional diffusing capacity of the lung. Ten patients with pulmonary emphysema and seven healthy volunteers were examined

Measurement of cerebrospinal fluid oxyge
✍ Greg Zaharchuk; Alastair J. Martin; Guy Rosenthal; Geoffery T. Manley; William P 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 728 KB

## Abstract Fluid‐attenuated inversion recovery (FLAIR) images obtained during the administration of supplemental oxygen demonstrate a hyperintense signal within the cerebrospinal fluid (CSF) that is likely caused by __T__~1~ changes induced by paramagnetic molecular oxygen. Previous studies demons

Improving the pharmacokinetic parameter
✍ Xiangyu Yang; Jiachao Liang; Johannes T. Heverhagen; Guang Jia; Petra Schmalbroc 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 715 KB

## Abstract One of the most powerful features of the dynamic contrast‐enhanced (DCE) MRI technique is its capability to quantitatively measure the physiological or pathophysiological environments assessed by the passage of contrast agent by means of model‐based pharmacokinetic analysis. The widely