𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Matrix effect in the quantitative analysis of urinary C-peptide by liquid chromatography/mass spectrometry

✍ Scribed by Colette Fierens; Linda M. Thienpont; Dietmar Stöckl; André P. De Leenheer


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
61 KB
Volume
14
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.


📜 SIMILAR VOLUMES


Quantitative analysis of terbinafine (La
✍ N. Brignol; R. Bakhtiar; L. Dou; T. Majumdar; F. L. S. Tse 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 122 KB 👁 2 views

A method using liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the determination of terbinafine in human and minipig plasma has been developed and validated. The method used positive-ion mode for monitoring terbinafine, and used a stable isotope labelled terbinafine as the internal sta

Analysis of the Artificial Sweetener Asp
✍ Guido C. Galletti; Paola Bocchini; A. M. Gioacchini; A. Roda 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 248 KB 👁 2 views

The establishment of analytical conditions for the determination of aspartame (N-L-a-aspartyl-L-phenylalanine 1-methyl ester) by means of high-performance liquid chromatographylelectrospray mass spectrometry (HPLCI ES-MS) was studied. Aspartame was analysed in the positive-ion mode at 3.05 kV probe

Application of liquid chromatography atm
✍ L. Ramos; R. Bakhtiar; F. Tse 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 61 KB 👁 2 views

Glyburide (glibenclamide) is widely prescribed in the treatment of Type II diabetes. A validated liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS) method for the determination of glyburide is reported. The method uses a stable isotope labeled gly

Quantitative Analysis of Mevinolinic Aci
✍ R. E. Calaf; M. Carrascal; E. Gelpí; J. Abian 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 136 KB 👁 2 views

Mevinolinic acid (MVA), the major active metabolite of Lovastatin in human blood, is analysed by microbore high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Quantification is carried out by using methylmevinolinic acid (MMVA) as internal standard. Positive-and

Reduction of Matrix-effects in Pesticide
✍ Mourabit, Fouad ;Deger, Ayse B. ;Gremm, Thomas J. ;Ouassini, Abdelmad ;Frimmel, 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 213 KB 👁 1 views

In this work analytical determination of some pesticides frequently used in Morocco and Turkey was carried out with solid-phase extraction (SPE) and gas chromatography-ion trap mass spectrometry (GC/ITD-MS). Because of coextracts from the SPE material and/or water sample, recovery values beyond 100