𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Mass transfer resistance of sterile plugs in shaking bioreactors

✍ Scribed by Christian Mrotzek; Tibor Anderlei; Hans-Jürgen Henzler; Jochen Büchs


Publisher
Elsevier Science
Year
2001
Tongue
English
Weight
424 KB
Volume
7
Category
Article
ISSN
1369-703X

No coin nor oath required. For personal study only.

✦ Synopsis


One of the mass transfer resistances for the gas exchange of shaking flasks is the sterile plug. The gas exchange through the sterile plug is described by an extended model of Henzler and Schedel [Bioprocess Eng. 7 (1991) 123]. Based on this model, a new method was developed to obtain the mass transfer resistance of various sterile closures. It consists of measuring the water evaporation rate of the shaking flask and is therefore very easily applied. Sterile plugs made of cotton, wrapped paper, urethane foam and fibreglass and caps made out of aluminium and silicone have been examined. Instead of the oxygen transfer coefficient (k(O(2))), which is commonly found in the literature, the carbon dioxide diffusion coefficient (D(CO(2))) is used to describe the mass transfer resistance of the sterile plug. The investigation revealed that this resistance is mainly dependent on the neck geometry and to a lesser extent on the plug material and density. The gas exchange of aluminium-caps was not reproducible.


📜 SIMILAR VOLUMES


Characterisation of the gas–liquid mass
✍ Ulrike Maier; Jochen Büchs 📂 Article 📅 2001 🏛 Elsevier Science 🌐 English ⚖ 378 KB

The maximum gas-liquid mass transfer capacity of 250ml shaking flasks on orbital shaking machines has been experimentally investigated using the sulphite oxidation method under variation of the shaking frequency, shaking diameter, filling volume and viscosity of the medium. The distribution of the l

New method to determine the mass transfe
✍ Tibor Anderlei; Christian Mrotzek; Stefan Bartsch; Ghassem Amoabediny; Cyril P. 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 225 KB

## Abstract In this paper a novel and easily applied method to measure the mass transfer resistance of the sterile closures (e.g. cotton plug) of shaken bioreactors is introduced. This method requires no investment in special equipment (e.g. an oxygen sensor) and can be performed with the materials

Device for sterile online measurement of
✍ Tibor Anderlei; Jochen Büchs 📂 Article 📅 2001 🏛 Elsevier Science 🌐 English ⚖ 609 KB

The oxygen transfer rate (OTR) is the most suitable measurable parameter to quantify the physiological state of a culture of aerobic microorganisms since most metabolic activities depend on oxygen consumption. Online measurement of the oxygen transfer rate in stirred bioreactors is state of the art

The effect of antifoam agents on mass tr
✍ Y. Kawase; M. Moo-Young 📂 Article 📅 1990 🏛 Springer 🌐 English ⚖ 477 KB

The influence of antifoam agents on the liquid-phase mass transfer coefficient in stirred tank and bubble column bioreactors is studied. A physical model based on a surface-renewal concept and additional data in 40-dm 3 bubble column bioreactor are presented. Comparisons between the physical model a