## Abstract A small highโirradiance laser ionization timeโofโflight mass spectrometer (LIโTOFMS) with orthogonal sample introduction was described. High irradiance of 6 ร 10^10^ W/cm^2^ at 532 nm from a Nd : YAG laser was applied in the experiment to get a high ionization degree in plasma and to di
Mass-analyzed threshold ionization (MATI) spectroscopy in a conventional time-of-flight mass spectrometer
โ Scribed by C. Jouvet; C. Dedonder-Lardeux; S. Martrenchard-Barra; D. Solgadi
- Publisher
- Elsevier Science
- Year
- 1992
- Tongue
- English
- Weight
- 420 KB
- Volume
- 198
- Category
- Article
- ISSN
- 0009-2614
No coin nor oath required. For personal study only.
โฆ Synopsis
We report a simple method for obtaining a mass-analyzed threshold ionization spectrum, equivalent to a zero kinetic energy photoelectron spectrum, using a standard supersonic beam coupled to a commercial time of flight mass spectrometer. The resolution achieved without any change in the conventional experimental arrangement is IO cm-' (full width at half maximum).