๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Mapping of oxygen tension and cell distribution in a hollow-fiber bioreactor using magnetic resonance imaging

โœ Scribed by Shane N. O. Williams; Rainer M. Callies; Kevin M. Brindle


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
915 KB
Volume
56
Category
Article
ISSN
0006-3592

No coin nor oath required. For personal study only.

โœฆ Synopsis


We mapped the distribution of dissolved oxygen and mammalian cells in a hollow-fiber bioreactor (HFBR) using 19 F NMR T 1 relaxation time imaging measurements on an infused perfluorocarbon probe molecule and diffusion-weighted 1 H NMR imaging of water. This study shows how cell density influences dissolved oxygen concentration in the reactor and demonstrates that NMR can play an important role in defining the biochemical engineering parameters required for optimization of HFBR design and operation.


๐Ÿ“œ SIMILAR VOLUMES


EPR oxygen mapping (EPROM) of engineered
โœ Scott J. Ellis; M. Velayutham; S. Sendhil Velan; Erik F. Petersen; Jay L. Zweier ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 328 KB

## Abstract A novel electron paramagnetic resonance (EPR)โ€based oxygen mapping procedure (EPROM) is applied to cartilage grown in a singleโ€, hollowโ€fiber bioreactor (HFBR) system. Chondrocytes harvested from the sterna of 17โ€dayโ€old chick embryos were inoculated into an HFBR and produced hyaline ca

Detection of acute renal ischemia in swi
โœ Sara K. Alford; Elizabeth A. Sadowski; Orhan Unal; Jason A. Polzin; Daniel W. Co ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 414 KB

## Abstract ## Purpose To determine the feasibility and sensitivity of blood oxygen levelโ€dependent (BOLD) magnetic resonance imaging (MRI) to detect acute renal ischemia, using a swine model, and to present the causes of variability and assess techniques that minimize variability introduced durin

In Vivo measurement of cerebral oxygen c
โœ J. Pekar; L. Ligeti; Z. Ruttner; R. C. Lyon; T. M. Sinnwell; P. van Gerderen; D. ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 390 KB

## Abstract We used ^17^O NMR imaging techniques to measure the H~2~^17^O concentration in a 0.8โ€ml voxel in the cat brain following injection of an arterial bolus of enriched H~2~^17^O and during inhalation of enriched ^17^O~2~. We also measured the H~2~^17^O concentration in arterial blood during

In vivo measurement of blood oxygen satu
โœ E. Mark Haacke; Song Lai; Jรผrgen R. Reichenbach; Karthikeyan Kuppusamy; Frank G. ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 145 KB ๐Ÿ‘ 2 views

A novel noninvasive magnetic resonance imaging (MRI) method was developed to determine in vivo blood oxygen saturation and its changes during motor cortex activation in small cerebral veins. Specifically, based on susceptibility measurements in the resting states, pial veins were found to have a mea