Detection of acute renal ischemia in swine using blood oxygen level-dependent magnetic resonance imaging

✍ Scribed by Sara K. Alford; Elizabeth A. Sadowski; Orhan Unal; Jason A. Polzin; Daniel W. Consigny; Frank R. Korosec; Thomas M. Grist


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
414 KB
Volume
22
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To determine the feasibility and sensitivity of blood oxygen level‐dependent (BOLD) magnetic resonance imaging (MRI) to detect acute renal ischemia, using a swine model, and to present the causes of variability and assess techniques that minimize variability introduced during data analysis.

Materials and Methods

BOLD MRI was performed in axial and coronal planes of the kidneys of five swine. Color R2* maps were calculated and mean R2* values and 95% confidence intervals (CIs) for the cortex and medulla were determined for baseline, renal artery occlusion and reperfusion conditions. Paired Student's t‐tests were used to determine significance.

Results

Mean R2* measurements increased from baseline during renal artery occlusion in the cortex (axial, 13.8–24.6 second^−1^; coronal, 14.4–24.7 second^−1^) and medulla (axial, 19.3–32.2 second^−1^; coronal, 20.1–30.7 second^−1^). These differences were significant for both the cortex (axial, P < 0.04; coronal, P < 0.005) and medulla (axial, P < 0.02; coronal, P < 0.0005). No significant change was observed in the contralateral kidney.

Conclusion

R2* values were significantly higher than baseline for medulla and cortex during renal artery occlusion. More variability exists in R2* measurements in the medulla than the cortex and in the axial than the coronal plane. J. Magn. Reson. Imaging 2005. © 2005 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Optimization of blood oxygenation level-
✍ Jianhui Zhong; Zhong Chen; W. Edmund Kwok; Scott Kennedy; Zhiyang You 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 260 KB

## Abstract ## Purpose To optimize timing parameters in an intermolecular double‐quantum coherence (iDQC) imaging pulse sequence for overall image signal‐to‐noise ratio (SNR) and blood oxygenation level‐dependent (BOLD) sensitivity for brain functional imaging. ## Material and Methods Fresh huma

In vivo measurement of blood oxygen satu
✍ E. Mark Haacke; Song Lai; Jürgen R. Reichenbach; Karthikeyan Kuppusamy; Frank G. 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 145 KB 👁 2 views

A novel noninvasive magnetic resonance imaging (MRI) method was developed to determine in vivo blood oxygen saturation and its changes during motor cortex activation in small cerebral veins. Specifically, based on susceptibility measurements in the resting states, pial veins were found to have a mea