Making the case for objective performance metrics in newborn screening by tandem mass spectrometry
✍ Scribed by Rinaldo, Piero ;Zafari, Saba ;Tortorelli, Silvia ;Matern, Dietrich
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 256 KB
- Volume
- 12
- Category
- Article
- ISSN
- 1080-4013
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The expansion of newborn screening programs to include multiplex testing by tandem mass spectrometry requires understanding and close monitoring of performance metrics. This is not done consistently because of lack of defined targets, and interlaboratory comparison is almost nonexistent. Between July 2004 and April 2006 (N = 176,185 cases), the overall performance metrics of the Minnesota program, limited to MS/MS testing, were as follows: detection rate 1:1,816, positive predictive value 37% (54% in 2006 till date), and false positive rate 0.09%. The repeat rate and the proportion of cases with abnormal findings actually been reported are new metrics proposed here as an objective mean to express the overall noise in a program, where noise is defined as the total number of abnormal results obtained using a given set of cut‐off values. On the basis of our experience, we propose the following targets as evidence of adequate analytical and postanalytical performance: detection rate 1:3,000 or higher, positive predictive value >20%, and false positive rate <0.3%. © 2006 Wiley‐Liss, Inc. MRDD Research Reviews 2006;12:255–261.
📜 SIMILAR VOLUMES
This work describes real examples of classes of drugs (drug candidates) whose quantitative determination in biological matrices by high performance liquid chromatography with electrospray tandem mass spectrometry (LC/MS/MS) may be hampered by interferences from drug-related biotransformation product
thesized and secreted from the zona glomerulosa of the A high-performance liquid chromatography -atmoadrenal cortex. Its primary physiological function is to spheric pressure chemical ionization -tandem mass regulate the metabolism of sodium and potassium ions, spectrometry (HPLC-APCI-MS/MS) referen
A systematic investigation was undertaken to study the effects of varying concentrations of additives in the acetonitrile/water high performance liquid chromatography mobile phase, especially formic acid and ammonium formate, on the negative ion electrospray response of a carboxylic acid compound. T
Preparative high performance liquid chromatography (HPLC) coupled to tandem mass spectrometry has been used successfully for the isolation of several drug metabolites from urine. Nuclear magnetic resonance (NMR) spectroscopy has been employed to determine the exact chemical structure of these metabo