## Abstract ## Purpose To assess the feasibility of contrast‐enhanced fat‐saturated three‐dimensional steady‐state free precession (FIESTA) imaging for contrast‐enhanced magnetic resonance (MR) portography. ## Materials and Methods Contrast‐enhanced fat‐saturated three‐dimensional fast spoiled g
Magnetization transfer contrast in fat-suppressed steady-state three-dimensional MR images
✍ Scribed by Duane P. Flame; W. Brad Pierce; Steven E. Harms; Richard H. Griffey
- Publisher
- John Wiley and Sons
- Year
- 1992
- Tongue
- English
- Weight
- 630 KB
- Volume
- 26
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
We demonstrate that magnetization transfer contrast can be used to improve the diagnostic utility of fat‐suppressed steady‐state three‐dimensional gradient‐recalled images. Fat suppression is achieved using a “jump‐return” pair of contiguous shaped pulses. No time interval exists between the pulses, and no RF echo is generated. The sequence normally produces images with “density” weighting. Preparation of the spin magnetization with off‐resonance frequency‐selective excitation creates magnetization transfer contrast which attenuates signal intensity in proportion to the exchange rate of magnetization from free water with magnetization from water bound to macromolecules or protons that have restricted mobility. The resulting images have excellent fat suppression with low sensitivity to motion since no subtraction is used. In addition, the mechanism of signal attenuation is independent of paramagnetic effects, and addition of Gd‐DTPA produces signal enhancement from vascularized regions of tissue. Examples are presented for the knee and breast, where the observation of pathology with signal enhancement from Gd‐DTPA is improved over conventional 3D fat‐suppressed images.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To assess the usefulness of non–contrast‐enhanced MR angiography using cardiac and navigator‐gated magnetization‐prepared three‐dimensional (3D) steady‐state free precession (SSFP) imaging for the diagnosis of diseases of the thoracic aorta. ## Materials and Methods Twenty
## Abstract ## Purpose To compare and evaluate images acquired with two different MR angiography (MRA) sequences, three‐dimensional (3D) half‐Fourier fast spin‐echo (FSE) and 3D true steady‐state free‐precession (SSFP) combined with two time‐spatial labeling inversion pulses (T‐SLIPs), for selecti
## Abstract ## Purpose: To compare nongated three‐dimensional (3D) contrast‐enhanced magnetic resonance angiography (CE‐MRA) with 3D‐navigated cardiac‐gated steady‐state free‐precession bright blood (3D‐nav SSFP) and noncontrast 2D techniques for ascending aorta dimension measurements. ## Materia