𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Magnetic resonance portography using contrast-enhanced fat-saturated three-dimensional steady-state free precession imaging

✍ Scribed by Yasuo Amano; Katsuya Takahama; Atsushi Nozaki; Maki Amano; Tatsuo Kumazaki


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
208 KB
Volume
19
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To assess the feasibility of contrast‐enhanced fat‐saturated three‐dimensional steady‐state free precession (FIESTA) imaging for contrast‐enhanced magnetic resonance (MR) portography.

Materials and Methods

Contrast‐enhanced fat‐saturated three‐dimensional fast spoiled gradient‐echo (SPGR) and FIESTA were performed as MR portography. In 10 cases, fat‐saturated three‐dimensional FIESTA was first performed and followed by fast SPGR, and the order of post‐contrast imaging was reversed in the other 10 cases. Signal‐to‐noise ratios (SNRs) and contrast‐to‐noise ratios (CNRs) were estimated for portal and visceral veins on the source images. The visualization of portal vein was scored on three‐dimensional MR portography. Portal venous system disorders were assessed using three‐dimensional MR portography.

Results

The SNRs, CNRs, and visual assessment of portal and visceral veins were significantly higher in contrast‐enhanced fat‐saturated three‐dimensional FIESTA than contrast‐enhanced fat‐saturated three‐dimensional fast SPGR (P < 0.05). The contrast‐enhanced fat‐saturated three‐dimensional FIESTA provided high venous signals even at 8 minutes after gadolinium injection. The abnormalities of portal venous system were well visualized with MR portography using contrast‐enhanced fat‐saturated three‐dimensional FIESTA.

Conclusion

Contrast‐enhanced fat‐saturated three‐dimensional FIESTA was valuable for MR portography, with flexible time window and high vascular signals. This imaging may allow for other post‐contrast imaging options before portography and release patients from consecutive breath‐holds. J. Magn. Reson. Imaging 2004;19:238–244. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Three-dimensional contrast-enhanced stea
✍ Jordin D. Green; Reed A. Omary; Brian E. Schirf; Richard Tang; James C. Carr; De 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 195 KB 👁 1 views

## Abstract ## Purpose To demonstrate the feasibility of three‐dimensional thick‐partition, contrast‐enhanced, catheter‐directed coronary artery magnetic resonance angiography (MRA) and test the hypothesis that three‐dimensional imaging improves coronary artery background contrast‐to‐noise ratio (

Non–contrast-enhanced MR angiography of
✍ Yasuo Amano; Katsuya Takahama; Shinichiro Kumita 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 304 KB 👁 1 views

## Abstract ## Purpose To assess the usefulness of non–contrast‐enhanced MR angiography using cardiac and navigator‐gated magnetization‐prepared three‐dimensional (3D) steady‐state free precession (SSFP) imaging for the diagnosis of diseases of the thoracic aorta. ## Materials and Methods Twenty

Non-contrast-enhanced MR portography wit
✍ Kotaro Shimada; Hiroyoshi Isoda; Tomohisa Okada; Toshikazu Kamae; Shigeki Arizon 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 482 KB

## Abstract ## Purpose To compare and evaluate images acquired with two different MR angiography (MRA) sequences, three‐dimensional (3D) half‐Fourier fast spin‐echo (FSE) and 3D true steady‐state free‐precession (SSFP) combined with two time‐spatial labeling inversion pulses (T‐SLIPs), for selecti

Measuring aortic diameter with different
✍ Silke Potthast; Lee Mitsumori; Luana A. Stanescu; Michael L. Richardson; Kelley 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 373 KB 👁 1 views

## Abstract ## Purpose: To compare nongated three‐dimensional (3D) contrast‐enhanced magnetic resonance angiography (CE‐MRA) with 3D‐navigated cardiac‐gated steady‐state free‐precession bright blood (3D‐nav SSFP) and noncontrast 2D techniques for ascending aorta dimension measurements. ## Materia