𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Magnetic Measurements of Critical Currents in Ag-BPSCCO Tapes: A Comparison

✍ Scribed by Lascialfari, A. ;Baldini, A. ;De Gennaro, S. ;Garrè, R. ;Peruzzi, A. ;Sangregorio, C.


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
198 KB
Volume
161
Category
Article
ISSN
0031-8965

No coin nor oath required. For personal study only.


📜 SIMILAR VOLUMES


Influence of thermomechanical treatment
✍ D.J. Brauer; D. Busch; R. Eujen; A. Gladun; J. Hüdepohl 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 377 KB

BSCCO-2223 tapes have been produced by the 'powder-in-tube' method with reproducible critical current densities of > 1 x 104 A cm-2 at 77 K and 5 x 104 A cm-2 at 4.2 K. Superconductivity at 77 K was retained in fields of up to 7 T. The influence of mechanical treatments (e.g. drawing, rolling and pr

A transformer for measuring 60 Hz loss a
✍ E.B. Forsyth; G.H. Morgan 📂 Article 📅 1974 🏛 Elsevier Science 🌐 English ⚖ 548 KB

To test samples of superconductor tape destined for use in power transmission cables, it is necessary to simulate the actual operating conditions for these cables A transformer in which the field parallel to one side of the superconductor sample is provided by cylindrical iron poles, produces these

Field dependence of critical currents in
✍ S. Elschner; E. Schachinger; J. Gerhold; M. Hubmann 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 454 KB

The critical currents of high quality sintered YBCO tubes are measured in two configurations, namely (a) the self-field generated by the transport current is superimposed by an applied circular magnetic field generated by a current through a central wire, and (b) the self-field is superimposed by an

The effect of interturn heat flow on the
✍ C.N. Carter; K.G. Lewis; B.J. Maddock 📂 Article 📅 1973 🏛 Elsevier Science 🌐 English ⚖ 696 KB

Cryostatic stabilization is appropriate for superconducting magnets producing steady fields over large volumes The measured recovery currents for a 10 cm bore 6.4 T experimental solenoid are compared with values derived from a stability analysis which includes heat flow from the resistive region to

A critical comparison of methods for the
✍ Sylvain Deville; Laurent Gremillard; Jérôme Chevalier; Gilbert Fantozzi 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 323 KB 👁 1 views

## Abstract Since the recent failure events of two particular series of zirconia femoral heads for total hip replacement prosthesis, a large decrease in the use of zirconia ceramics for orthopaedic implants has been observed. In spite of the biomedical success of this material during the last 10 ye