## Abstract Dynamic contrast‐enhanced MRI is used to estimate microvascular parameters by tracer kinetics analysis. The time for the contrast agent to travel from the artery to the tissue of interest (bolus arrival time (BAT)) is an important parameter that must be measured in such studies because
Localized measurement of atherosclerotic plaque inflammatory burden with dynamic contrast–enhanced MRI
✍ Scribed by Huijun Chen; Jianming Cai; Xihai Zhao; Hunter Underhill; Hideki Ota; Minako Oikawa; Li Dong; Chun Yuan; William S. Kerwin
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 255 KB
- Volume
- 64
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Inflammation plays an important role in progression and rupture of atherosclerotic plaque. Dynamic contrast–enhanced MRI has been proposed as a tool to evaluate inflammation in vivo by measuring the transfer constant and partial plasma volume, which are influenced by inflammation. This study sought to demonstrate the ability of dynamic contrast–enhanced MRI to provide localized measurements of transfer constant and partial plasma volume within plaque regions of different compositions. In order to do that, a highly automatic procedure for localized measurement of dynamic contrast–enhanced MRI parameters was developed. In 47 subjects, the average transfer constant and partial plasma volume were highest in loose matrix and fibrous tissue and substantially lower in intraplaque hemorrhage, lipid rich/necrotic core, and calcification. In addition, except for hemorrhage and calcification, statistically significant differences of transfer constant and partial plasma volume were observed for any pair of these components. This suggests that transfer constant and partial plasma volume could be helpful to differentiate different plaque components and that dynamic contrast–enhanced MRI has the potential to assess inflammatory burden in specific regions. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Breakdown of the blood‐brain barrier (BBB), occurring in many neurological diseases, has been difficult to measure noninvasively in humans. Dynamic contrast‐enhanced magnetic resonance imaging measures BBB permeability. However, important technical challenges remain and normative data f
## Abstract ## Purpose To measure the cerebrovascular volume and blood‐brain barrier (BBB) permeability indices in hippocampus and cerebellum of patients with mild cognitive impairment (MCI) using dynamic contrast‐enhanced MRI (DCE‐MRI), and compare to that of normal controls. ## Materials and Me