𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Laser desorption/Fourier transform mass spectrometry of steroids

✍ Scribed by Eric T. Fung; Charles L. Wilkins


Publisher
John Wiley and Sons
Year
1988
Tongue
English
Weight
284 KB
Volume
15
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Laser Desorption Fourier Transform Mass
✍ D. SrziΔ‡; S. MartinoviΔ‡; Lj. PaΕ‘a ToliΔ‡; N. Kezele; S. KazaziΔ‡; Lj. SenkoviΔ‡; S. πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 297 KB πŸ‘ 1 views

Natural polymers, humic acid and lignins, were investigated by laser desorption (LD) Fourier transform mass spectrometry. In the vapor phase under LD conditions only positive ions of humic acid were observed up to m/z 700. Under the same conditions all the lignins investigated prefer to form negativ

Laser desorption fourier transform mass
✍ Mildred L. Coates; Charles L. Wilkins πŸ“‚ Article πŸ“… 1985 πŸ› John Wiley and Sons 🌐 English βš– 364 KB

Laser desorption mass spectra of malto-oligomers, including starch, have been obtained using Fourier transform mass spectrometry. Fragmentations of these oligomers have been examined after doping with metal salts to obtain cation-attachment ions. Doping starch with NaCl, KBr and Ag,O results in anal

Time-of-flight effects in matrix-assiste
✍ T.-P. E. Sze; T.-W. Dominic Chan πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 137 KB πŸ‘ 2 views

The time-of-flight effect in Fourier transform mass spectrometry (FTMS) with an external ion source was quantified. The time-of-flight profiles of ions of different masses were measured by stepping the time interval between the ionization pulse and the gating of the trapping voltage (T gate ). The o

252Cf plasma desorption fourier transfor
✍ S. K. Viswanadham; D. M. Hercules; R. R. Weller; C. S. Giam πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 205 KB πŸ‘ 2 views

The ions produced by "'Cf plasma desorption are detected by Fourier transform ion cyclotron resonance techniques. Results for CsI and N,N,N-trimethyl-p-aminophenolate iodide show the feasibility of the technique with high resolution (up to 11 000 at m / z 23) and good signal-to-noise ratio (up to 72

Sequential mass spectrometry and MSn ana
✍ Diane C. Tutko; Kent D. Henry; Brian E. Winger; Howard Stout; Mark Hemling πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 211 KB πŸ‘ 2 views

This note demonstrates that accurate mass and MS/MS data can be rapidly and easily obtained using an automated matrix-assisted laser desorption/ionization Fourier transform MS procedure for multiple samples. Multiple ionization techniques were used simultaneously in order to introduce sample and mas