## Abstract Many diagnostic MRI sequences demand reliable and uniform fat suppression. Multipoint water–fat separation methods, which are based on chemical‐shift induced phase differences, have shown great success in the presence of field inhomogeneities. This work presents a computationally effici
Joint estimation of water/fat images and field inhomogeneity map
✍ Scribed by D. Hernando; J. P. Haldar; B. P. Sutton; J. Ma; P. Kellman; Z.-P. Liang
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 253 KB
- Volume
- 59
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Water/fat separation in the presence of B~0~ field inhomogeneity is a problem of considerable practical importance in MRI. This article describes two complementary methods for estimating the water/fat images and the field inhomogeneity map from Dixon‐type acquisitions. One is based on variable projection (VARPRO) and the other on linear prediction (LP). The VARPRO method is very robust and can be used in low signal‐to‐noise ratio conditions because of its ability to achieve the maximum‐likelihood solution. The LP method is computationally more efficient, and is shown to perform well under moderate levels of noise and field inhomogeneity. These methods have been extended to handle multicoil acquisitions by jointly solving the estimation problem for all the coils. Both methods are analyzed and compared and results from several experiments are included to demonstrate their performance. Magn Reson Med 59:571–580, 2008. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Robust fat suppression techniques are required for many clinical applications. Multi‐echo water‐fat separation methods are relatively insensitive to B~0~ field inhomogeneity compared to the fat saturation method. Estimation of this field inhomogeneity, or field map, is an essential and
## Abstract Improved selectivity to one chemical shift component was obtained using simultaneous slice‐selective and chemical shift‐selective excitation in sequences with usual spin‐echo refocusing. The new type of sequences can be applied on modern whole‐body units and permits multislice operation
## Abstract Chemical shift based methods are often used to achieve uniform water–fat separation that is insensitive to __B__~o~ inhomogeneities. Many spin‐echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time‐dependent phase shifts caused by wa