𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Joint estimation of water/fat images and field inhomogeneity map

✍ Scribed by D. Hernando; J. P. Haldar; B. P. Sutton; J. Ma; P. Kellman; Z.-P. Liang


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
253 KB
Volume
59
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Water/fat separation in the presence of B~0~ field inhomogeneity is a problem of considerable practical importance in MRI. This article describes two complementary methods for estimating the water/fat images and the field inhomogeneity map from Dixon‐type acquisitions. One is based on variable projection (VARPRO) and the other on linear prediction (LP). The VARPRO method is very robust and can be used in low signal‐to‐noise ratio conditions because of its ability to achieve the maximum‐likelihood solution. The LP method is computationally more efficient, and is shown to perform well under moderate levels of noise and field inhomogeneity. These methods have been extended to handle multicoil acquisitions by jointly solving the estimation problem for all the coils. Both methods are analyzed and compared and results from several experiments are included to demonstrate their performance. Magn Reson Med 59:571–580, 2008. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Multiresolution field map estimation usi
✍ Wenmiao Lu; Brian A. Hargreaves 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 458 KB

## Abstract Many diagnostic MRI sequences demand reliable and uniform fat suppression. Multipoint water–fat separation methods, which are based on chemical‐shift induced phase differences, have shown great success in the presence of field inhomogeneities. This work presents a computationally effici

Field map estimation with a region growi
✍ Huanzhou Yu; Scott B. Reeder; Ann Shimakawa; Jean H. Brittain; Norbert J. Pelc 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 752 KB

## Abstract Robust fat suppression techniques are required for many clinical applications. Multi‐echo water‐fat separation methods are relatively insensitive to B~0~ field inhomogeneity compared to the fat saturation method. Estimation of this field inhomogeneity, or field map, is an essential and

Highly selective water and fat imaging a
✍ Fritz Schick; Jürgen Forster; Jürgen Machann; Peter Huppert; Claus D. Claussen 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 670 KB

## Abstract Improved selectivity to one chemical shift component was obtained using simultaneous slice‐selective and chemical shift‐selective excitation in sequences with usual spin‐echo refocusing. The new type of sequences can be applied on modern whole‐body units and permits multislice operation

Iterative decomposition of water and fat
✍ Scott B. Reeder; Angel R. Pineda; Zhifei Wen; Ann Shimakawa; Huanzhou Yu; Jean H 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 855 KB

## Abstract Chemical shift based methods are often used to achieve uniform water–fat separation that is insensitive to __B__~o~ inhomogeneities. Many spin‐echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time‐dependent phase shifts caused by wa