✦ Synopsis


Abstract

Chemical shift based methods are often used to achieve uniform water–fat separation that is insensitive to B~o~ inhomogeneities. Many spin‐echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time‐dependent phase shifts caused by water–fat chemical shift. This work demonstrates that symmetrically acquired echoes cause artifacts that degrade image quality. According to theory, the noise performance of any water–fat separation method is dependent on the proportion of water and fat within a voxel, and the position of echoes relative to the SE. To address this problem, we propose a method termed “iterative decomposition of water and fat with echo asymmetric and least‐squares estimation” (IDEAL). This technique combines asymmetrically acquired echoes with an iterative least‐squares decomposition algorithm to maximize noise performance. Theoretical calculations predict that the optimal echo combination occurs when the relative phase of the echoes is separated by 2π/3, with the middle echo centered at π/2+π__k__ (k = any integer), i.e., (–π/6+π__k__, π/2+π__k__, 7π/6+π__k__). Only with these echo combinations can noise performance reach the maximum possible and be independent of the proportion of water and fat. Close agreement between theoretical and experimental results obtained from an oil–water phantom was observed, demonstrating that the iterative least‐squares decomposition method is an efficient estimator. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Improved fat suppression using multipeak
✍ Richard Kijowski; Michael A. Woods; Kenneth S. Lee; Kuya Takimi; Huanzhou Yu; An 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 391 KB

## Abstract ## Purpose To evaluate and quantify improvements in the quality of fat suppression for fast spin‐echo imaging of the knee using multipeak fat spectral modeling and IDEAL fat‐water separation. ## Materials and Methods T~1~‐weighted and T~2~‐weighted fast spin‐echo sequences with IDEAL

T1- and T2-weighted fast spin-echo imagi
✍ Scott B. Reeder; Huanzhou Yu; Jane W. Johnson; Ann Shimakawa; Jean H. Brittain; 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 598 KB

## Abstract ## Purpose To compare the __i__terative __d__ecomposition of water and fat with __e__cho __a__symmetry and __l__east‐squares estimation (IDEAL) method with fat‐saturated T1‐weighted (T~1~W) and T~2~W fast spin‐echo (FSE) and short‐TI inversion recovery (STIR) imaging of the brachial pl

Separation of fat and water in fast spin
✍ Peter A. Hardy; R. Scott Hinks; Jean A. Tkach 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 555 KB

## Abstract A method for suppressing fat in fast spin‐echo imaging with the three‐point Dixon technique is described. The method differs from the three‐point Dixon method used in conventional spin‐echo imaging in that the readout gradient instead of a radio‐frequency pulse is shifted. This method p