Highly selective water and fat imaging applying multislice sequences without sensitivity to B1 field inhomogeneities

✍ Scribed by Fritz Schick; Jürgen Forster; Jürgen Machann; Peter Huppert; Claus D. Claussen


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
670 KB
Volume
38
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Improved selectivity to one chemical shift component was obtained using simultaneous slice‐selective and chemical shift‐selective excitation in sequences with usual spin‐echo refocusing. The new type of sequences can be applied on modern whole‐body units and permits multislice operation. Spatial‐spectral excitation is based on prior research in this field, but the proposed improved version provides off‐center slice excitation by the usual processing of the RF pulse envelopes. In addition, no irregular gradient shapes are necessary. The required B~0~ homogeneity of the new method is similar to conventional “fat‐sat” techniques. In contrast to fat‐sat methods, selectivity to water is not reduced by unavoidable mis‐adjustments of the transmitter or B~1~ field inhomogeneities in the newly developed approach. Thus, the reported method has the potential to replace standard frequency selective fat‐sat sequences for most applications.