A new candidate reference method is presented for the determination of thyroxine in serum. The method is based on isotope dilution-liquid chromatography/tandem mass spectrometry using electrospray for ionization. The internal standard used was 13 C 6 -thyroxine, sample pretreatment consisted of prot
Isotope dilution-gas chromatography/mass spectrometry and liquid chromatography/electrospray ionization-tandem mass spectrometry for the determination of triiodo- L-thyronine in serum
✍ Scribed by Linda M. Thienpont; Colette Fierens; André P. De Leenheer; Louise Przywara
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 96 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
✦ Synopsis
Isotope dilution-gas chromatography/mass spectrometry (ID-GC/MS) and isotope dilution-liquid chromatography/tandem mass spectrometry (ID-LC/MS/MS) methods have been developed for an determination of triiodothyronine (T3) in serum and their potential as candidate reference methods investigated. In both methods, 13 C 9 -T3 was used as internal standard. Sample pretreatment consisted of deproteinization, extraction and high performance liquid chromatography (HPLC) purification. Conversion of serum thyroxine (T4) to T3 was controlled by adding 13 C 6 -T4. For GC/MS, T3 and 13 C 9 -T3 were converted to the N,O-di-heptafluorobutyryl (HFB) methyl ester derivatives and monitored at m/z 844 and 853. For LC/MS with electrospray ionization, the transitions m/z 652/661 to 606/614 were monitored. For use of the methods as candidate reference methods, special attention was paid to the calibration and the measurement protocol (duplicate analysis of each sample on three occasions). Evaluation of the ID-GC/MS and ID-LC/MS/MS methods showed the absence of interference by reverse T3 and T4, a limit of detection of 100 pg (GC/MS) and 18 pg (LC/MS), a recovery of 100 AE 1.5% (95% confidence interval) and good precision (the total coefficient of variation, n = 6, was typically 1.5%). In addition to the recovery study, the accuracy of the methods was proven by method comparison (ID-GC/MS vs. LC/MS/MS) on three sera, showing a maximum deviation of 1.1%. Finally, the ID-GC/MS method was applied for measurement of 10 different human sera with a T3 concentration range from 0.6 to 7.3 ng/mL.
📜 SIMILAR VOLUMES
The behaviour of 5-methyl-2'-deoxycytidine (m 5 dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra
A method based on liquid chromatography (LC) combined with electrospray ionization tandem mass spectrometry for the analysis of the frequency of formation of 8-hydroxydeoxyguanosine (8OHdGuo), a biomarker of oxidative damage to DNA, has been developed. This analytical technique has the advantage ove
Electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)) and liquid chromatography coupled with on-line mass spectrometry (LC/MS/MS) were applied to characterize saponins in crude extracts from Panax ginseng. The MS(n) data of the [M - H](-) ions of saponins can provide structural in