The behaviour of 5-methyl-2'-deoxycytidine (m 5 dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra
Determination of 8-Hydroxydeoxyguanosine in Biological Tissue by Liquid Chromatography/Electrospray Ionization-Mass Spectrometry/Mass Spectrometry
β Scribed by Jose Serrano; Carlos M. Palmeira; Kendall B. Wallace; Douglas W. Kuehl
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 340 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
A method based on liquid chromatography (LC) combined with electrospray ionization tandem mass spectrometry for the analysis of the frequency of formation of 8-hydroxydeoxyguanosine (8OHdGuo), a biomarker of oxidative damage to DNA, has been developed. This analytical technique has the advantage over gas chromatography combined with mass spectrometry of not requiring analyte derivatization, and over LC combined with ultraviolet and electrochemical detection of being chemospecific The method was evaluated by determining increased frequency of formation of SOHdGuo in male Sprague-Dawky rats given a single intraperitoneal dose of Adriamycin" compared to control rats. Detection of one oxidized deoxyguanosine per 5 x 10s deoxyguanosines was readily achieved.
π SIMILAR VOLUMES
A method for the separatory determination of bile acid 3-sulfates by liquid chromatography (LC)/electrospray ionization (ESI) mass spectrometry (MS) was developed. The sulfates were characterized by an abundant pseudomolecular ion [ M Γ H ]with a doubly charged ion [ M Γ 2H ] 2-, and the ratio of th
Linalool, nerol, geraniol, citronellol and a-terpineol were phosphorylated and the products purified by adsorption chromatography on XAD-2. High performance liquid chromatography-tandem mass spectrometry (LC-MSMS) analysis using the electrospray ionization technique (ESI) revealed the occurrence of
The quantitative determination of nucleotides from DNA modiΓed by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liqui
Mass spectrometry of ochratoxin A (OTA) and B (OTB) under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was studied. ESI offers higher sensitivities and less fragmentation than APCI. A sensitive LC/MS/MS method for the determination of ochratoxin A (OTA) in human
Disaccharides and linear oligosaccharides were labeled with p-aminobenzoic ethyl ester (ABEE) chromophore and analyzed by negative ion electrospray ionization mass spectrometry (ESIMS). The formation of glycosylamines rather than reductive amination in the labeling reaction produced many characteris