𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Ionization of anabolic steroids by adduct formation in liquid chromatography electrospray mass spectrometry

✍ Scribed by Oscar J. Pozo; Peter Van Eenoo; Koen Deventer; Frans T. Delbeke


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
336 KB
Volume
42
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The ionization of 46 anabolic steroids has been studied. The absence of basic or acidic moieties in most of these analytes makes their direct ionization as [M + H]^+^ by atmospheric pressure interfaces difficult. The formation of adducts with different components of the mobile phase has been found to be an efficient way to ionize anabolic steroids by electrospray. Different mobile phases using methanol (MeOH) or acetonitrile as organic solvent and HCOOH, Na^+^ or NH~4~^+^ as additives have been tested to favor the adduct formation. A direct correlation between the chemical structure of the anabolic steroid and the possibility to ionize it in a particular chromatographic condition has been found. According to their ionization, anabolic steroids can be divided into seven different groups depending on both the nature and the relative position of their functional groups. The formation of different adducts such as [M + Na + MeOH]^+^ or [M + H + CH~3~ CN βˆ’ H~2~O]^+^ is required in order to ionize some of these groups and the optimal mobile phase composition for each group of anabolic steroids is proposed. Despite the ionization limitations due to their chemical structure, most of tested anabolic steroids could be ionized using the adduct formation approach. Copyright Β© 2007 John Wiley & Sons, Ltd.


πŸ“œ SIMILAR VOLUMES


Liquid chromatography/mass spectrometry
✍ Antti Leinonen; Tiia Kuuranne; Risto Kostiainen πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 119 KB πŸ‘ 1 views

## Abstract The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods we

Determination of 8-Hydroxydeoxyguanosine
✍ Jose Serrano; Carlos M. Palmeira; Kendall B. Wallace; Douglas W. Kuehl πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 340 KB πŸ‘ 2 views

A method based on liquid chromatography (LC) combined with electrospray ionization tandem mass spectrometry for the analysis of the frequency of formation of 8-hydroxydeoxyguanosine (8OHdGuo), a biomarker of oxidative damage to DNA, has been developed. This analytical technique has the advantage ove

Quantitative determination of DNA adduct
✍ Siethoff, Christoph; Feldmann, Ingo; Jakubowski, Norbert; Linscheid, Michael πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 147 KB πŸ‘ 2 views

The quantitative determination of nucleotides from DNA modiÐed by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liqui

Reaction monitoring of platinum(II) comp
✍ Peter ZΓΆllner; Andrea Zenker; Markus Galanski; Bernhard K. Keppler; Wolfgang Lin πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 192 KB

Cisplatin and four structurally related platinum(II) complexes were incubated with guanosine 5'-monophosphate (5'-GMP) in water at 37 degrees C. The adduct formation reactions were monitored with cation- and anion-exchange liquid chromatography/electrospray ionization mass spectrometry. In addition

Electrospray ionization mass spectrometr
✍ Carlo Giorgio Zambonin; Francesco Palmisano πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 79 KB πŸ‘ 2 views

The behaviour of 5-methyl-2'-deoxycytidine (m 5 dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra

Analysis of Phosphorylated Terpenes by E
✍ Iris Ney; Elke JΓ€ger; Markus Herderich; Peter Schreier; Wilfried Schwab πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 362 KB πŸ‘ 2 views

Linalool, nerol, geraniol, citronellol and a-terpineol were phosphorylated and the products purified by adsorption chromatography on XAD-2. High performance liquid chromatography-tandem mass spectrometry (LC-MSMS) analysis using the electrospray ionization technique (ESI) revealed the occurrence of