## Abstract The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods we
Ionization of anabolic steroids by adduct formation in liquid chromatography electrospray mass spectrometry
β Scribed by Oscar J. Pozo; Peter Van Eenoo; Koen Deventer; Frans T. Delbeke
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 336 KB
- Volume
- 42
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1182
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
The ionization of 46 anabolic steroids has been studied. The absence of basic or acidic moieties in most of these analytes makes their direct ionization as [M + H]^+^ by atmospheric pressure interfaces difficult. The formation of adducts with different components of the mobile phase has been found to be an efficient way to ionize anabolic steroids by electrospray. Different mobile phases using methanol (MeOH) or acetonitrile as organic solvent and HCOOH, Na^+^ or NH~4~^+^ as additives have been tested to favor the adduct formation. A direct correlation between the chemical structure of the anabolic steroid and the possibility to ionize it in a particular chromatographic condition has been found. According to their ionization, anabolic steroids can be divided into seven different groups depending on both the nature and the relative position of their functional groups. The formation of different adducts such as [M + Na + MeOH]^+^ or [M + H + CH~3~ CN β H~2~O]^+^ is required in order to ionize some of these groups and the optimal mobile phase composition for each group of anabolic steroids is proposed. Despite the ionization limitations due to their chemical structure, most of tested anabolic steroids could be ionized using the adduct formation approach. Copyright Β© 2007 John Wiley & Sons, Ltd.
π SIMILAR VOLUMES
A method based on liquid chromatography (LC) combined with electrospray ionization tandem mass spectrometry for the analysis of the frequency of formation of 8-hydroxydeoxyguanosine (8OHdGuo), a biomarker of oxidative damage to DNA, has been developed. This analytical technique has the advantage ove
The quantitative determination of nucleotides from DNA modiΓed by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liqui
Cisplatin and four structurally related platinum(II) complexes were incubated with guanosine 5'-monophosphate (5'-GMP) in water at 37 degrees C. The adduct formation reactions were monitored with cation- and anion-exchange liquid chromatography/electrospray ionization mass spectrometry. In addition
The behaviour of 5-methyl-2'-deoxycytidine (m 5 dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra
Linalool, nerol, geraniol, citronellol and a-terpineol were phosphorylated and the products purified by adsorption chromatography on XAD-2. High performance liquid chromatography-tandem mass spectrometry (LC-MSMS) analysis using the electrospray ionization technique (ESI) revealed the occurrence of