Isotope dilution-gas chromatography/mass spectrometry (ID-GC/MS) and isotope dilution-liquid chromatography/tandem mass spectrometry (ID-LC/MS/MS) methods have been developed for an determination of triiodothyronine (T3) in serum and their potential as candidate reference methods investigated. In bo
Ion-exchange electrospray ionization liquid chromatography mass spectrometry and tandem mass spectrometry of alkanolamines in wetland vegetation exposed to sour-gas contaminated groundwater
✍ Scribed by J. V. Headley; K. M. Peru; L. C. Dickson
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 91 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
✦ Synopsis
Electrospray ionization with ion-exchange liquid chromatography mass spectrometry was used for the determination of selected alkanolamines in wetland vegetation exposed to sour-gas contaminated groundwater. Analytes were determined using filtered water extracts of the vegetation with no further cleanup, preconcentration or derivatization steps. Quantification was performed using either selected ion monitoring of the protonated molecular ions (MH ) or the loss of water transition in product ion scans. Confirmations were based on comparison of the respective product ion scans with authentic standards. Instrumental detection limits were attainable in the picogram range (20-40 pg) for diisopropanolamine (DIPA), monoethanolamine, diethanolamine, methyldiethanolamine and triethanolamine. Successful application of the procedure is demonstrated for the determination of DIPA in over 50 samples, collected from a sour-gas contaminated wetland and a control site. For roots, shoots, berries, seeds, grasses and leaves, the recovery was 90 AE 25 % relative standard deviation (RSD) with a detection limit of 20 ng/g. In general, the technique was rugged (based on a study period of 18 months in which over 175 runs were conducted), relatively fast ($25 min per sample for a batch of 10 samples) and gave detection limits a factor of 5 lower than a conventional ion chromatography method.
📜 SIMILAR VOLUMES
## Halogenation and nitration of biomolecules have been proposed as key mechanisms of host defense against bacteria, fungi, and viruses. Reactive oxidants also have the potential to damage host tissue, and they have been implicated in disease. In the current studies, we describe specific, sensitiv
## Measurement of cyclic nucleotides by electrospray ionization mass spectrometry constitutes an unequivocal quantitative and qualitative technique superior to the established estimation methods of UV spectroscopy, radioimmunoassay (RIA), enzyme-linked immunosorbent assay (ELISA) and other mass spe
## Abstract An ultra‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPLC‐ESI‐MS__^n^__) has been developed for structural characterization and identification of multi‐constituents in Yiqing Capsule, a well‐known combined herbal remedy prepared from the extract m