𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Ion-exchange chromatography of biologically important phosphate esters and other compounds

✍ Scribed by Kenneth C. Blanshard; Indrajit Das; Alan J. Thomas


Publisher
Elsevier Science
Year
1977
Tongue
English
Weight
864 KB
Volume
83
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


Borate complexed sugars, sugar phosphates, and nucleotides present in tissue extracts were separated and quantitated in 4 hr. An anion-exchange resin column and a programmed borate/acetate buffer gradient were used. Sugar residues were determined by a very sensitive orcinol/H,SO, reaction. Samples required little preparation, and recovery of standard compounds added to tissue extracts was quantitative.


πŸ“œ SIMILAR VOLUMES


Determination of inositol phosphates and
✍ Robert E. Smith; Ronald A. MacQuarrie πŸ“‚ Article πŸ“… 1988 πŸ› Elsevier Science 🌐 English βš– 583 KB

Ion chromatography has been applied to the simultaneous, multi-component determination of biologically important anions. More than 20 different biologically important anions were separated on high performance ion-exchange columns and detected using chemically suppressed conductivity. Application of

Selectivity properties of sephadex gels
✍ Joseph Lerner; Abner I. Schepartz πŸ“‚ Article πŸ“… 1969 πŸ› Elsevier Science 🌐 English βš– 768 KB

The selectivity properties of Sephadex gels toward various metabolic phosphates (nucleotides and coenzymes) have been examined by column chromatography using distilled water as eluent. These compounds are grouped within a range of ICa values from 0.22 to 0.39 on Sephadex G-ro."Sephadex G-15 differs

Assay of nucleotides and other phosphate
✍ Hans W. Heldt; Archie R. Portis; Ross McC.Lilley; Annemarie Mosbach; Chong Ja Ch πŸ“‚ Article πŸ“… 1980 πŸ› Elsevier Science 🌐 English βš– 683 KB

This report describes a method for a sensitive assay of phosphate-containing metabolites in chloroplasts. The first step was to preincubate the chloroplasts with inorganic [3ZP]phosphate in order to label the stromal phosphate pool. On illumination, the intermediates of the reductive CO, fixation cy

Application of ion-exchange resin coated
✍ Pauncz, Judit KΓ‘dΓ‘r πŸ“‚ Article πŸ“… 1981 πŸ› John Wiley and Sons 🌐 English βš– 290 KB

## Abstract A thin‐layer chromatographic method is described for sulfonamides and some other chemotherapeutic compounds. Ion‐exchange resin precoated plates (Fixion 50 Γ— 8 Na^+^, Chinoin, Budapest or Polygram Ionex‐25 SA‐Na, Macherey‐Nagel and Co.,DΓΌren, FRG) are employed with Na~2~HPO~4~ or Na‐ace