𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Ion chromatographic determination of metals in biocompatibility testing

✍ Scribed by Buldini, Pier Luigi ;Mevoli, Anna ;Sharma, Jawahar Lal


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
199 KB
Volume
50
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


The increasing numbers of materials used in surgical implants require a wide spectrum of tests to evaluate their biocompatibility. The release of metals is an important additional feature for determining the suitability for clinical applications of biomaterials such as ceramics and metals. Due to the difficulty of performing time-consuming experiments in vivo, one approach for rapidly determining the suitability of biomaterials and their interactions with the tissues with which they will come in contact is to perform in vitro tests, based on cell culture analysis, using solutions that reproduce the cleavage and binding capabilities of body fluids and tissues. The present work reports on the application of ion chromatography to the simultaneous determination of some metal ions in a few biologic media. Agar-Agar solution, "199 medium," and betadine and Schiff's reagents were selected as some of the most representative biologic simulating solutions. A method is recommended for the pretreatment of the sample with minimal reagent addition since it is very rich in organic compounds and cannot be analyzed without pretreatment. The proposed procedure requires the sample to be subjected to oxidative UV photolysis for about 60 min in an UV digester at 85°± 5°C, followed by the ion chromatographic determination. Lead (II), cadmium (II), iron (III), copper (II), nickel (II), zinc (II), and cobalt (II) simultaneously were determined at g/L levels.


πŸ“œ SIMILAR VOLUMES


Thin-layer Chromatographic Determination
✍ G. Alemany; M. AkaΓ’rir; C. RossellΓ³; A. Gamundi πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 215 KB πŸ‘ 2 views

A TLC method for the quantitative determination of epinephrine, norepinephrine and dopamine in rat plasma is described. After deprotenization, catecholamines were adsorbed on acid-alumina and acetylated. The acetyl derivatives were extracted using a C18 minicolumn, resolved on HPTLC plates and quant

Sonoelectroanalytical Determination of H
✍ Joanna L. Hardcastle; Richard G. Compton πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 127 KB πŸ‘ 1 views

Fish gill mucous is used as a nondestructive biomarker for the detection of heavy metals by sono-square-wave anodic stripping voltammetry (sono-SWASV). The mucous sample was obtained by gently rinsing the rainbow trout (Salmo gairdneri) with a solution of borate buffer at pH 7. A glassy carbon elect

Rapid high-performance liquid chromatogr
✍ B. Calahorra; M. A. Campanero; B. SΓ‘daba; J. R. Azanza πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 55 KB πŸ‘ 1 views

A simple, rapid and reproducible high-performance liquid chromatographic method for the quantitative determination of cefepime in human plasma was developed. Ceftazidime was used as internal standard. Chromatography was performed on a reversed-phase encapped column (Hypersil BDS C 18 ). The samples,