𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Intrinsic fat suppression in TIDE balanced steady-state free precession imaging

✍ Scribed by Dominik Paul; Jürgen Hennig; Maxim Zaitsev


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
599 KB
Volume
56
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A novel fat‐suppressed balanced steady‐state free precession (b‐SSFP) imaging method based on the transition into driven equilibrium (TIDE) sequence with variable flip angles is presented. The new method, called fat‐saturated (FS)‐TIDE, exploits the special behavior of TIDE signals from off‐resonance spins during the flip angle ramp. As shown by simulations and experimental data, the TIDE signal evolution for off‐resonant isochromats during the transition from turbo spin‐echo (TSE)‐like behavior to the true fast imaging with steady precession (TrueFISP) mode undergoes a zero crossing. The resulting signal notch for off‐resonant spins is then used for fat suppression. The efficiency of FS‐TIDE is demonstrated in phantoms and healthy volunteers on a 1.5T system. The resulting images are compared with standard TrueFISP data with and without fat suppression. It is demonstrated that FS‐TIDE provides a fast and stable means for homogenous fat suppression in abdominal imaging while maintaining balanced SSFP‐like image contrast and signal‐to‐noise ratio (SNR). The scan time of FS‐TIDE is not increased compared to normal TrueFISP imaging without fat suppression and identical k‐space trajectories. Because of the intrinsic fat suppression, no additional preparation is needed. Possible repetition times (TRs) are not firmly limited to special values and are nearly arbitrary. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Fat-suppressed steady-state free precess
✍ Brian A. Hargreaves; Shreyas S. Vasanawala; Krishna S. Nayak; Bob S. Hu; Dwight 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 333 KB

## Abstract Fully refocused steady‐state free precession (SSFP) is a rapid, efficient imaging sequence that can provide diagnostically useful image contrast. In SSFP, the signal is refocused midway between excitation pulses, much like in a spin‐echo experiment. However, in SSFP, the phase of the re

Spiral balanced steady-state free preces
✍ Krishna S. Nayak; Brian A. Hargreaves; Bob S. Hu; Dwight G. Nishimura; John M. P 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 455 KB

## Abstract Balanced steady‐state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood–myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced S

Flow effects in balanced steady state fr
✍ M. Markl; M.T. Alley; C.J. Elkins; N.J. Pelc 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 876 KB

## Abstract An analysis of the effect of flow on 2D fully balanced steady state free precession (SSFP) imaging is presented. Transient and steady‐state SSFP signal intensities in the presence of steady and pulsatile flow were simulated using a matrix formalism based on the Bloch equations. Various

Optimized balanced steady-state free pre
✍ O. Bieri; K. Scheffler 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 654 KB

## Abstract Balanced steady‐state free precession (bSSFP) suffers from a considerable signal loss in tissues. This apparent signal reduction originates from magnetization transfer (MT) and may be reduced by an increase in repetition time or by a reduction in flip angle. In this work, MT effects in

Multiple repetition time balanced steady
✍ Tolga Çukur; Dwight G. Nishimura 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 864 KB

## Abstract Although balanced steady‐state free precession (bSSFP) imaging yields high signal‐to‐noise ratio (SNR) efficiency, the bright lipid signal is often undesirable. The bSSFP spectrum can be shaped to suppress the fat signal with scan‐efficient alternating repetition time (ATR) bSSFP. Howev

Imaging periodic currents using alternat
✍ Giedrius T. Buračas; Thomas T. Liu; Richard B. Buxton; Lawrence R. Frank; Eric C 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 585 KB

## Abstract Existing functional brain MR imaging methods detect neuronal activity only indirectly via a surrogate signal such as deoxyhemoglobin concentration in the vascular bed of cerebral parenchyma. It has been recently proposed that neuronal currents may be measurable directly using MRI (ncMRI