𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Imaging periodic currents using alternating balanced steady-state free precession

✍ Scribed by Giedrius T. Buračas; Thomas T. Liu; Richard B. Buxton; Lawrence R. Frank; Eric C. Wong


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
585 KB
Volume
59
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Existing functional brain MR imaging methods detect neuronal activity only indirectly via a surrogate signal such as deoxyhemoglobin concentration in the vascular bed of cerebral parenchyma. It has been recently proposed that neuronal currents may be measurable directly using MRI (ncMRI). However, limited success has been reported in neuronal current detection studies that used standard gradient or spin echo pulse sequences. The balanced steady‐state free precession (bSSFP) pulse sequence is unique in that it can afford the highest known SNR efficiency and is exquisitely sensitive to perturbations in free precession phase. It is reported herein that when a spin phase‐perturbing periodic current is locked to an RF pulse train, phase perturbations are accumulated across multiple RF excitations and the spin magnetization reaches an alternating balanced steady state (ABSS) that effectively amplifies the phase perturbations due to the current. The alternation of the ABSS signal therefore is highly sensitive to weak periodic currents. Current phantom experiments employing ABSS imaging resulted in detection of magnetic field variations as small as 0.15nT in scans lasting for 36 sec, which is more sensitive than using gradient‐recalled echo imaging. Magn Reson Med, 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Alternating repetition time balanced ste
✍ J. Leupold; J. Hennig; K. Scheffler 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 791 KB

## Abstract A novel balanced SSFP technique for the separation or suppression of different resonance frequencies (e.g., fat suppression) is presented. The method is based on applying two alternating and different repetition times, TR~1~ and TR~2~. This RF scheme manipulates the sensitivity of balan

Spiral balanced steady-state free preces
✍ Krishna S. Nayak; Brian A. Hargreaves; Bob S. Hu; Dwight G. Nishimura; John M. P 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 455 KB

## Abstract Balanced steady‐state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood–myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced S

Flow effects in balanced steady state fr
✍ M. Markl; M.T. Alley; C.J. Elkins; N.J. Pelc 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 876 KB

## Abstract An analysis of the effect of flow on 2D fully balanced steady state free precession (SSFP) imaging is presented. Transient and steady‐state SSFP signal intensities in the presence of steady and pulsatile flow were simulated using a matrix formalism based on the Bloch equations. Various

Optimized balanced steady-state free pre
✍ O. Bieri; K. Scheffler 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 654 KB

## Abstract Balanced steady‐state free precession (bSSFP) suffers from a considerable signal loss in tissues. This apparent signal reduction originates from magnetization transfer (MT) and may be reduced by an increase in repetition time or by a reduction in flip angle. In this work, MT effects in

Multiple repetition time balanced steady
✍ Tolga Çukur; Dwight G. Nishimura 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 864 KB

## Abstract Although balanced steady‐state free precession (bSSFP) imaging yields high signal‐to‐noise ratio (SNR) efficiency, the bright lipid signal is often undesirable. The bSSFP spectrum can be shaped to suppress the fat signal with scan‐efficient alternating repetition time (ATR) bSSFP. Howev

Rapid Fourier imaging using steady-state
✍ R. C. Hawkes; S. Patz 📂 Article 📅 1987 🏛 John Wiley and Sons 🌐 English ⚖ 875 KB

Reversal of the read gradient in a SSFP imaging experiment allows a full spin echo to be collected in the interval T between successive rfpulses. Orthogonal gradient pulses are used to dephase and subsequently rephase the transverse magnetization each T enabling 2D or 3D Fourier techniques. The mini