## Abstract Balanced steady‐state free precession (SSFP) imaging is limited by off‐resonance banding artifacts, which occur with periodicity 1/TR in the frequency spectrum. A novel balanced SSFP technique for widening the band spacing in the frequency response is described. This method, called wide
Alternating repetition time balanced steady state free precession
✍ Scribed by J. Leupold; J. Hennig; K. Scheffler
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 791 KB
- Volume
- 55
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A novel balanced SSFP technique for the separation or suppression of different resonance frequencies (e.g., fat suppression) is presented. The method is based on applying two alternating and different repetition times, TR~1~ and TR~2~. This RF scheme manipulates the sensitivity of balanced SSFP to off‐resonance effects by a modification of the frequency response profile. Starting from a general approach, an optimally broadened stopband within the frequency response function is designed. This is achieved with a TR~2~ being one third of TR~1~ and an RF‐pulse phase increment of 90°. With this approach TR~2~ is too short (∼1 ms) to switch imaging gradients and is only used to change the frequency sensitivity. Without a significant change of the spectral position of the stopband, TR~1~ can be varied over a range of values (∼2.5–4.5 ms) while TR~2~ and phase cycling is kept constant. On‐resonance spins show a magnetization behavior similar to balanced SSFP, but with maximal magnetization at flip angles about 10° lower than in balanced SSFP. The total scan time is increased by about 30% compared to conventional balanced SSFP. The new technique was applied on phantoms and volunteers to produce rapid, fat suppressed images. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Although balanced steady‐state free precession (bSSFP) imaging yields high signal‐to‐noise ratio (SNR) efficiency, the bright lipid signal is often undesirable. The bSSFP spectrum can be shaped to suppress the fat signal with scan‐efficient alternating repetition time (ATR) bSSFP. Howev
## Abstract Existing functional brain MR imaging methods detect neuronal activity only indirectly via a surrogate signal such as deoxyhemoglobin concentration in the vascular bed of cerebral parenchyma. It has been recently proposed that neuronal currents may be measurable directly using MRI (ncMRI
## Abstract Balanced‐steady‐state free precession (b‐SSFP) functional magnetic resonance imaging (fMRI) encompasses several recently developed methods that utilize b‐SSFP acquisition for fMRI. Short repetition time (__T__~R~) and readout durations of b‐SSFP allow distortion‐free acquisition, 3D ima
## Abstract Balanced steady‐state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood–myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced S
## Abstract A spin‐locked balanced steady‐state free‐precession (slSSFP) pulse sequence is described that combines a balanced gradient‐echo acquisition with an off‐resonance spin‐lock pulse for fast MRI. The transient and steady‐state magnetization trajectory was solved numerically using the Bloch