## Abstract The formerly proposed concept for magnetization transfer imaging (MTI) using balanced steady‐state free precession (SSFP) image acquisitions is in this work extended to nonbalanced protocols. This allows SSFP‐based MTI of targets with high susceptibility variation (such as the musculosk
Optimized balanced steady-state free precession magnetization transfer imaging
✍ Scribed by O. Bieri; K. Scheffler
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 654 KB
- Volume
- 58
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Balanced steady‐state free precession (bSSFP) suffers from a considerable signal loss in tissues. This apparent signal reduction originates from magnetization transfer (MT) and may be reduced by an increase in repetition time or by a reduction in flip angle. In this work, MT effects in bSSFP are modulated by a modification of the bSSFP sequence scheme. Strong signal attenuations are achieved with short radio frequency (RF) pulses in combination with short repetition times, whereas near full, i.e., MT‐free, bSSFP signal is obtained by a considerable prolongation of the RF pulse duration. Similar to standard methods, the MT ratio (MTR) in bSSFP depends on several sequence parameters. Optimized bSSFP protocol settings are derived that can be applied to various tissues yielding maximal sensitivity to MT while minimizing contribution from other impurities, such as off‐resonances. Evaluation of MT in human brain using such optimized bSSFP protocols shows high correlation with MTR values from commonly used gradient echo (GRE) sequences. In summary, a novel method to generate MTR maps using bSSFP image acquisitions is presented and factors that optimize and influence this contrast are discussed. Magn Reson Med 58:511–518, 2007. © 2007 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Recently, a new and fast three‐dimensional imaging technique for magnetization transfer ratio (MTR) imaging has been proposed based on a balanced steady‐state free precession protocol with modified radiofrequency pulses. In this study, optimal balanced steady‐state free precession MTR p
## Abstract Balanced steady‐state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood–myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced S
## Abstract An analysis of the effect of flow on 2D fully balanced steady state free precession (SSFP) imaging is presented. Transient and steady‐state SSFP signal intensities in the presence of steady and pulsatile flow were simulated using a matrix formalism based on the Bloch equations. Various
## Abstract Although balanced steady‐state free precession (bSSFP) imaging yields high signal‐to‐noise ratio (SNR) efficiency, the bright lipid signal is often undesirable. The bSSFP spectrum can be shaped to suppress the fat signal with scan‐efficient alternating repetition time (ATR) bSSFP. Howev
## Abstract Balanced‐steady‐state free precession (b‐SSFP) functional magnetic resonance imaging (fMRI) encompasses several recently developed methods that utilize b‐SSFP acquisition for fMRI. Short repetition time (__T__~R~) and readout durations of b‐SSFP allow distortion‐free acquisition, 3D ima