The study has been performed concerning the influence of the design of helium liquefaction and refrigeration (4,5 K) plants (number of cooling stages in the area of regenerative-expander stages and methods of expander connection, appearance of liquefaction area, availability of nitrogen precoolin~)
The relationships between different thermodynamic parameters of a helium liquefaction and refrigeration (4.5 K) plant are defined. The plant was designed according to a schematic diagram with four cooling stages: with (and without) preliminary nitrogen cooling, with two expanders connected in series